18529092692

Home >> News
News
Huawei OSN3500 check if the HARD_BAD alarm is reported on the GSCC of the main control board
| 2025-11-21|Back

  1. The Optix OSN3500 SSN4GSCC determines the alarm based on the single board that reports the alarm. if it is not reported by the master board. refer to Checking whether the crossover board or the service board reports the HARD_BAD alarm.
  2. If it is reported by the main control board, do the following judgment processing.
    1. Optix OSN3500 SSN4GSCC If parameter 1 = 0xFF, parameter 2 to parameter 3 = 0xFF, meaningless. At this time, it means that the alarm is reported to the main control board failure, the specific failure is determined according to parameters 4 and 5, and the site can replace the alarm reported to the main control board.

      Parameter name

      Parameter Meaning

      Parameter 4

      For the main control board, if parameter 1=0xFF, parameter 4 represents a different meaning.

      For GSCC board, the meaning of parameter 4 is as follows:
      • bit[0]=1 indicates that the software detects the hardware set bad.
      • bit[3]=1 means the internal chip is bad.
      • bit[4]=1 indicates that the 20M crystal is faulty.
      • bit[5]=1 indicates 25M crystal failure.
      • bit[6]=1 indicates the first 38M clock failure.
      • bit[7]=1 indicates a second 38M clock failure.
      For SCA single board, the meaning of parameter 4 is as follows:
      • bit[0]=1 indicates that the software detects a bad hardware placement.
      • bit[2]=1 indicates a programmable logic device failure.
      • bit[3]=1 indicates a 32M clock failure.
      • bit[4]=1 indicates a 33M crystal failure.
      • bit[5]=1 indicates a 25M crystal failure.
      • bit[6]=1 indicates the first 38M clock failure.
      • bit[7]=1 indicates a second 38M clock failure.

      A bit of 1 indicates that the alarm exists, and a bit of 0 indicates that the alarm does not exist. Multiple bits can be in effect at the same time.

      Parameter 5

      For the master board, if parameter 1 is 0xFF, parameter 5 represents a different meaning.

      For GSCC single board, the meaning of parameter 5 is as follows:
      • bit[0]=1 indicates that the 3.3V power module of this board is faulty.
      • bit[1]=1 indicates that the Ethernet port (ETH) between the master and the network management is faulty.
      • bit[2]=1 indicates a failure of the Ethernet port for inter-board communication between the master and other single boards.
      • bit[3]=1 indicates an internal network port failure between the master and backup master.
      • bit[4]=1 indicates a 1.8432M crystal failure.
      For SCA single board, the meaning of parameter 5 is as follows:
      • bit[0]=1 indicates a 3.3V power module failure on this board.
      • bit[1]=1 indicates that the Ethernet port (ETH) between the master and the network management has failed.
      • bit[2]=1 indicates a failure of the Ethernet port for inter-board communication between the master and other single boards.
      • bit[3]=1 indicates an internal network port failure between the master and backup master.
      • bit[4]=1 indicates a 125M clock failure.

      A bit of 1 indicates that the alarm exists, and a bit of 0 indicates that the alarm does not exist. Multiple bits can be in effect at the same time.

    2. If parameter 1 ≠ 0xFF, parameter 2 to parameter 5 = 0xFF, meaningless. Parameter 1 indicates that a service single board or cross single board 2K/8K line failure is detected, and the specific value represents the single board board number of the 2K/8K line failure. The steps are handled as follows:
      • Parameter 1 Slot business board failure, please replace this single board to solve the problem and check whether the slot is backward pin.

The related technical information and SDH equipment troubleshooting procedures in this chapter are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), and are reproduced and retained! Our company specializes in the sale of Huawei SDH optical transmission equipment,SDH transmission equipment.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板