Description of the problem
When the performance of Huawei SDH transmission equipment is found to be missing a certain line board performance. Then the single board query for this single board performance returns a value of NULL.
Processing
First, query whether this single board is working, and execute the command :cfg-get-workstat:bid
#9-44:szhw [][][2011-10-22 23:43:09+08:00]>
:cfg-get-workstat:5
BD-WORK-STATUS
BID WORK-STAT
5 not work
Total records :1
The board is found to be not working, and the performance is not monitored if the board is not working.
Then I analyzed the reason why the single board did not start, firstly, I replaced the single board to another slot, and found that it could start normally, so I judged that it was a slot problem. After replacing the subrack, the problem was solved.
Root cause
The root cause of this problem is that the veneer fails to start due to a slot failure, and thus the performance of the veneer cannot be queried.
Solution
Emergency recovery measures: Replace the slot or replace the subrack.
The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co.( www.opticaltrans.com), please retain! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.