Low-order SNCP and MSP co-grouping with service interruption but no alarm problem
| 2025-11-21|Back

Description of the problem

The lower service point of a low-order SNCP ring is configured on a node of a ring-multiplexed segment ring, and the SNCP service is configured on the working channel of the ring-multiplexed segment ring, but the protection of this SNCP is not configured on the ring-multiplexed segment ring. The service point on the working channel of this low-order SNCP service is connected to another site of the ring multiplexing segment, and a power failure at this site causes the multiplexing segment ring to be inverted, and then the low-order SNCP service is interrupted, but there are no alarms for this low-order SNCP service.

Processing

First, check whether the inversion of this multiplexing segment is successful, and then query the K-byte events of the whole ring and the inversion page to see whether the inversion is successful.

By querying the K-byte events and the page switching situation of the whole ring, the page switching is correct at the power-down point and the stations at both ends, and all other stations on the ring have entered the pass-through page correctly, which indicates that the rewinding of the multiplexing segment is correct.

Then check whether the reversal event of the SNCP where the interrupted service is located is correct, and find that there is no reversal event generated by this SNCP at the point of time of power down, indicating that this SNCP has been working in the working channel, and because the working channel of this SNCP has already been selected in the protection channel of the multiplexing segment due to the reversal of multiplexing segments, and because the corresponding channels of the reversed site of the multiplexing segment ring have been configured with the service, thus the misconnection occurs, resulting in the low-power segment. A misconnection occurs, resulting in a low-order SNCP service interruption without an alarm.

Root Cause

The root cause of this issue is that the service is misconnected when the service point on the SNCP is powered down, resulting in service interruption without alarm.

Solution

Emergency recovery measures: Forcibly switch SNCP to the protected channel.

Complete solution: Configure the protection of SNCP on the ring of multiplexed segments and configure it as recoverable.

Recommendations and Summary

Low-order jobs are configured on the multiplexed segment ring, and misconnections cannot be avoided. When low-order SNCP is coupled with MSPs, it is recommended that SNCP jobs not be configured on the multiplexed segment ring.


The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), and are reproduced with permission! Our company specializes in the sale of Huawei SDH optical transmission equipment,SDH transmission equipment.


Sell Huawei Metro1000 Equipment_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply Huawei Metro1000 equipment_Troubleshooting_Installation_Tuning_Technical Index_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板