OSN1500 device network element AUX single board reset causes PIU to report bd_status
| 2025-11-21|Back

Description of the problem

The following alarm occurs on Huawei OSN1500 device network elements without operation, and you need to find out the cause of the alarm.

235439 10 BD_STATUS MJ end 2013-03-11 02:30:59 2013-03-11 02:31:42 0xff 0xff 0xff 0xff 0xff 0xff 0xff

235440 18 BD_STATUS MJ end 2013-03-11 02:31:13 2013-03-11 02:32:05 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff

235441 19 BD_STATUS MJ end 2013-03-11 02:31:13 2013-03-11 02:32:05 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff

The single board information is as follows:

:cfg-get-board.

INSTALLED-BOARD

BID BD-TYPE ACTIVE-STATE

3 ssr1sld4 active

4 ssq1sl4 active

5 ssq1sl4 active

6 ssr2pd1 active

7 ssr2pd1 active

8 ssr2pd1 active

10 aux active

11 ssn1slq1 active

12 ssn1slq1 active

13 ssr1sld4 active

15 ssn1d12s active

17 ssn1d12s active

18 piu active

19 piu active

20 ssr1fan active

80 ssq2ecxl active

81 ssq2ecxl active

82 gscc active

83 gscc active

Total records :19

BD_STATUS

Processing

Due to the limited subrack space of Huawei OSN1500 network elements (including 1500A and 1500B), the PIU board's in-position line is sent to the master through the AUX, so that the AUX soft reset will cause the PIU to report the BD_STATUS alarm at the same time. This is a hardware feature of the OSN1500.

Root Cause

The OSN1500 network element PIU's presence line is sent to the master through the AUX, so the AUX soft reset will cause the PIU to report the BD_STATUS alarm at the same time.

Solution

1, the first suspected bd_status alarm known problem: in-position line jitter. According to the relevant case troubleshooting ruled out.

2, because the PIU is reported at the same time, disappear at the same time, it is impossible to be two PIU at the same time hardware problems reported not in position.

3, observe 10 # board AUX alarm time and PIU alarm time in the report time and end time seems to have a little connection.

4, check the AUX errlog.log, found that the day of the soft reset record, the time with the report of the BD_STATUS alarm time is consistent.

2013-03-10 [18:31:00] 0x0a 0xf0000010 0x00000001

This shows that the AUX reported BD_STATUS because a soft reset occurred.

5, then why PIU reported BD_STATUS, and what is the connection with AUX? After inquiring the information, we know the reason that the PIU of 1500 network element is sent to the master control through AUX, so the soft reset of AUX will cause PIU to report BD_STATUS alarm at the same time.


The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain the reproduction! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Sell Huawei OSN1500 Equipment_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply Huawei OSN1500 equipment_Troubleshooting_Installation_Tuning_Technical Index_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板