Description of the problem
Huawei OSN3500 devices use SLQ16 single boards on optical ports 1 & 2 to configure ring multiplexing segments unsuccessfully. Network management reports
"Non-parity board for checksum, error code 38742". Device version is: V100R008C02B01L (5.21.18.50)
Alarm message
Non-parity board for calibration, error code 38742
Processing
Ask the engineer to delete the SLQ16 single board first and then re-create the single board, then configure the ring multiplexing segment, normal.
Root Cause
Because the Huawei OSN3500 device supports software pairing, and the single board is a multi-optical port STM-16 single board, it should be able to be configured as a ring multiplexing segment, not because of the existence of this limitation. It is suspected that there is a problem with host processing.
After R&D analyzes the collected network element database, it is found that the single board fails to obtain the attribute of "support optical path sharing for multiplexed segments". The host detects this attribute when it creates a multiplexed segment in a non-parallel slot, and reports that it is not supported if both corresponding single boards do not have this attribute. It is suspected that the host does not assign this attribute to the board when it creates the board.
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), and are reproduced and retained! Our company specializes in the sales of Huawei SDH optical transmission equipment, SDH transmission equipment.