Description of the problem
T2000V2R7C03SPC003 network administrator creates a VB with bridge type 802.1Q on the N1EMS2 board of Huawei OSN3500 device, and prompts "This command is not supported, error code 38737" when connecting to a port, and the port cannot be connected.
Host version: 5.21.19.22 N1EMS2:1.15
Processing
1:After uploading data and reconfiguring the fault remains;
2: Change the bridge type and the problem still exists. Check the description of the single board which also supports 802.1Q;
3: Check the version of the supporting table host with the single board is also supporting; network management requirements for the R7C02, the site R7C03 should also be no problem, the use of R8 network management configuration failure remains;
4: Collect relevant data to the R & D analysis, confirmed that the R7C03/R8 network management support the command to set the type of bridge, but 5.21.19.22 hosts are not supported. There is a problem with the downward compatibility of the network management;
6:Use R7C02 network management configuration temporary solution, followed by R & D to give a complete solution.
Root cause
1: Inconsistency between network management and network element data;
2: 802.1Q type bridge is not supported, only 802.1d or mixed mode;
3: The host is not matched with the single board;
4: Problems in the cooperation between the network management and the host;
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.