Description of the problem
After the Huawei OSN3500 SDH transmission equipment SSN4EGS4 single board enables the external port, the reported ETH_LOS and IN_PWR_LOW alarms do not disappear, and the IN_PWR_LOW alarm is not reported under normal conditions.
Main control board 5.21.18.50
SSN4EGS4 version 1.14
Alarm information
ETH_LOS and IN_PWR_LOW Alarms
Processing
1. Check that the SSN4EGS4 single board does not input signals, and after initializing the network element alarms, the ETH_LOS and IN_PWR_LOW alarms are still reported.
2, check the host and board version to confirm matching, replace the SSN4EGS4 board, the same failure phenomenon
3、After confirming the SSN4EGS4 board version 1.14 software problem, upgrade to version 1.17 to solve the problem.
Root cause
1. False alarm IN_PWR_LOW.
2、Version mismatch
3、Single board failure
4、Software problems
This chapter of related technical information and SDH equipment troubleshooting process by the Shenzhen Optical Transmission Network Technology Co., Ltd. collected and organized (www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.