Description of the problem
Huawei OSN3500 optical boards will insert MSRDI alarms back in case of receiving RLOS, but under what circumstances will HP_RDI alarms be inserted back? Some switches and other devices use the HP_RDI alarm as a criterion for a bad channel, which leads to service interruption, so it is necessary to understand the HP_RDI alarm back-insertion situation.
Alarm Information
No
Processing
1. For OSN3500 2500 +, 155622, and metro1000 devices, if this VC4 channel is configured with a low-order service, the optical port receives the R_LOS alarm, and then the HP_RDI alarm is inserted back for this channel.
2. For OSN3500 2500+, 155622, and metro1000 devices, if this VC4 channel is configured for high-order services (VC4 level), after the optical port receives the R_LOS alarm, the HP_RDI alarm will be inserted back to this channel if the overhead mode of this single board is terminal, and the HP_RDI alarm will not be inserted back to this channel if the overhead mode of this single board is pass-through. _RDI alarm.
3. For NGSDH and OSN9500 devices, if the VC4 channel is configured for low-order service and 1+1 linear multiplexing segment is configured at the same time, the optical port will not insert the HP_RDI alarm back to the channel after receiving the R_LOS alarm, and the HP_RDI alarm will be inserted back to the channel in the case of not configuring the 1+1 linear multiplexing segment.
4. For NGSDH and OSN9500 equipment, if the VC4 channel is configured for high-order services, the optical port will not insert the HP_RDI alarm after receiving the R_LOS alarm.
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Co. (www.opticaltrans.com), please retain! Our company specializes in the sales of Huawei SDH optical transmission equipment,SDH transmission equipment.