OSN3500 SSN2PQ1A E1 to VC12 mapping pattern inconsistent
| 2025-11-21|Back

Description of the problem

During the station opening process of a 3G network in country G, it was found that a large number of Node Bs could not come online, the wireless side checked that the configuration was fine, the transmission side also confirmed that the configuration was fine, and the fiber optic link was tested to be fine. The link end-to-end scenario is

RNC --- optical port docking --- OSN3500---- optical port docking ----MW (harrison) ----E1 docking -----Node B.

The microwave side of the third party also confirms that the link and configuration are fine.


Alarm messages

Transmission side: None

Harrison microwave: none

Wireless side: site status DOWN


Processing

Through the R & D and Harrison engineering discussion and research, finally found that our OSN products and Harrison products E1 to VC12 mapping mode is not right, our OSN products are bit asynchronous mode by default, and can not change the settings, and Harrison microwave has bit asynchronous and throughput mode, can be configured to change. Through communication with Harrision engineers, they cooperated to change the mode of microwave site connected to NodeB site by E1 to bit asynchronous, and the Node B site was up, and the problem was solved.


Root cause

1, tested the OSN network link configuration is not a problem, in and harrison microwave docking place to hang table return test, the link is normal. Preliminary exclusion of OSN transmission link problems;

2, the wireless RNC configuration is not a problem, and the replacement of the single board test, the device is normal, the same also ruled out the possibility of Node B side of the hardware and configuration abnormalities;

3, the third-party microwave link was tested for loopback, and the link is also normal;

4, OSN and microwave optical interface docking, timing is also no problem, to rule out the problem of timing matching.

Through the above points ruled out the hardware failure and docking timing problems, the problem may still be in our OSN and Harrison microwave docking parameters.


Suggestions and Summary

When our OSN products and third-party products are docked, we should not only consider the matching problem of timing, but also consider some parameters and underlying technical issues, when encountering docking problems, the first line should not be in a hurry to hang up the table to test, but also contact with the R&D in time, so as to solve the problem in a timely manner.


The relevant technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain the reproduction! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板