Description of the problem
After a frontline engineer sets up an N2PQ1 single-board port inner loop on an OSN3500 R8C02 version network element, the loopback is never automatically released, . The loopback was eventually lifted manually. On the other hand, other line veneers can automatically release the loopback after setting the loopback.
Alarm Message
:cfg-set-loop:7,1,inloop
51026 7 LOOP_ALM MN start 2011-08-11 20:27:26 None 0x01 0x00 0x01 0x00 0x00 0x00
Process
Manually unlock the tributary single board loopback.
Root cause
The mainframe has been modified in R7 pole later versions, and all branch circuit boards in R7 and later mainframe versions do not support unloopback. All line boards support automatic unloopback.
Recommendation and Summary
With the command :cfg-set-loop:7,1,inloop
Set inloop on port 1 of board 7.
You can use the following command to query whether the port currently in loopback state can be released automatically
:cfg-get-autoclearlist.
AUTOCLEAR-RECORD
optype bid port path
portloop 7 1 0
Tabular output method with corresponding fields:
OPTYPE : Type to be automatically cleared
BID : Board ID
PORT : Port number
PATH : Channel number
This means that port 1 of board 7 can be automatically released from loopback.