OSN3500 Transmission Device ETH Port Setting Problem Causes Device to Fail to Log In
| 2025-11-21|Back

Problem Description

A newly built OSN3500 device cannot be logged on or PINGed through in the field.

Alarm message

None
Processing
1, the scene through the portable machine with a network cable directly connected to the device can not PING through, replace a number of network cables are so, while the portable machine can be connected to other devices can be logged on normally, can be excluded from the network cable, portable and other external reasons;
2, by other devices through the ECC can be logged on to the device, can be the device for the alarm, the performance of querying their respective operations, can be further confirmed to be the device itself communication problems;
3, OSN3500 equipment on the OSN3500 device has dual master control, master and backup inversion, retain a master control (17/18 are trying), remove other single board only retain a master control and other operations, are unable to solve the problem, can be ruled out that other single board problems lead to the possibility of the problem;
4, apply for a new master control and an AUX single board, replacement is invalid;
5, cfg-set-oamport query the status of the ETH port to confirm that the port is open, and also closed. open, also carried out close and then open operation, invalid;
6, consult the R & D, R & D to provide a data collection tool to collect data, after analyzing the reasons for: the Ethernet port is not UP, no routing information, only two routes, so can not ping through;
7, with cm-get-lanaccess query to confirm that the status of the close, set to open can be normal. The problem is solved. The problem is solved.
Root cause
1. network cable problem;
2. main control board or AUX single board failure;
3. device subrack problem;
4. software setting problem
Suggestions and summaries
Command line analysis:
Name cfg-set-oamport
Function Sets the maintenance port switch
Command Level System Monitor
Open Range User Level
Version 5.36.17.XX&5.21.17.XX
Input Format :cfg-set-oamport:PortType, state; number of parameters = 2, parameter block repeats
Input Parameters Parameter position Meaning and value of parameter
1 Port type
COM: COM port
ETH: ETH port
OAM: OAM port
F_f: F&f port
2 Port status: open / close (port default: all ports are closed except ETH port which is open)
Name: cm-set-lanaccess cm-set-lanaccess
Function Sets the Ethernet access control to close or open the Ethernet driver.
Command Level System maintenance
Open Scope User Level
Versions All OSP versions
Input format Position definition, number of parameters = 2, repeat mode: no repeat
Input parameters Parameter position Parameter value
1 LAN NO: Ethernet number; numeric format;
2 STATE: Ethernet allow/prohibit access flag
Customized format, string
close-prohibit (0), open-allow (1)
Output format Error code
NSERR_LAN_ERR_PARA: parameter error
NSERR_LAN_DBF_FAIL: database operation error
NSERR_LAN_FUNCALL_FAIL: function call error
NSERR_LAN_SUCCESS: operation successful
Example :cm-set-lanaccess:0,close;
Cautions 1. Don't use this command easily, or you will not be able to use the management terminal! And after closing the Ethernet access, the extended ECC function working through Ethernet will not work!
Remarks 1. At present, only the case where the Ethernet number is set to 0 is allowed.
Which cm-set-lanaccess corresponding to the entry is the network management on the Ethernet access control, the command is stored library, if set to close, unplugging the board can not be restored.

The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板