OSN3500 high level services recorded inconsistent performance issues on different circuit boards
| 2025-11-21|Back

Description of the problem

OSN3500 has a high order service coming from a third party equipment doing VC4 pass-through on our equipment. The line veneers passing through are SSN3SL16A, SSN1SL64,SSN2SLQ16. SSN3SL16A veneer does not detect SES but SSN1SL64,SSN2SLQ16 veneer detects 2 SES; or SSN3SL16A veneer detects 5 SES but SSN1SL64, SSN2SLQ16 veneer detects 18 SES. there may be a momentary AUO. SSN2SLQ16 veneer detects 18 SES. there may be a momentary AUAIS alarm, which may not be observed because of alarm filtering.


Processing

There are two sources of SES performance: the first is BER generation, if there is a serious BER on the channel, it will generate SES. the second is SES from alarms, the channel level alarms that will lead to SES performance are as follows: AUAIS, AULOP, HPTIM, HPUNEQ. when the performance module goes to inspect the alarm module to see if there is any alarm, if there is no alarm at the sampling time point, the performance module will not consider that there is an alarm, and therefore no SES will be generated. If there is no alarm at the sampling time point, the performance module will not consider that there is an alarm, and therefore no SES will be generated. Therefore, the record of SES performance generated by an alarm depends on the status of the alarm and the read time of the software patrol task.

The alarm patrol task of the product software in the SSN3SL16A board is 200ms, while the alarm patrol task of the product software in the SSN1SL64 and SSN2SLQ16 boards is 1 second. If the alarm is pulsed, for example, a 100ms alarm is generated, for SSN3SL16A single board at this time, the product is reported to the platform, the next cycle of no alarm, this time the alarm is reported to the platform is over, if the platform samples at this time, the alarm will not be read, and therefore does not record the SES, but for the SSN1SL64,SSN2SLQ16 single board even if the 100ms alarm is generated, the next alarm is reported to the platform, the next alarm is reported to the platform is over, if the platform samples at this time, it will not be read, so it does not record the SES. However, for SSN1SL64,SSN2SLQ16, even if an alarm is generated for 100ms, the next alarm reporting cycle is 1 second later, but the platform sampling will read the alarm within this 1 second, so the SES performance will be recorded.


Root Cause

The root cause of this problem is that when the alarms are pulsed, the alarm patrol cycles of different boards are different, resulting in different alarm states detected by different boards when the platform is doing performance sampling, and thus different numbers of SESs are recorded.






This chapter of related technical information and SDH equipment troubleshooting process by the Shenzhen Optical Transmission Network Technology Limited collection ( www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板