Description of the problem
A line board of an OSN3500 device is found to report R_LOS and R_LOF alarms at the same time, but the alarms do not start at the same time.
The customer feels abnormal and needs to locate the cause.
:alm-get-curdata:4,0
NUM BID EID SEVERITY STATE START-TIME END-TIME PARA1 PARA2 PARA3 PARA4 PARA5
335538685 4 R_LOF CR start 2012-10-22 20:32:07 None 0x02 0x00 0x01 0xff 0xff
335538686 4 R_LOF CR start 2012-10-22 20:32:07 None 0x01 0x00 0x01 0xff 0xff
335539737 4 R_LOS CR start 2012-10-23 05:19:45 None 0x01 0x00 0x01 0xff 0xff
Processing
First, use the command :alm-set-bsrep:4,enable to turn on the alarm display switch reported by the board to the host, and find that the following data is frequently reported on the Navigotor:
#9-1019:szhw [1019-Ilam ][][2012-10-23 06:32:45+00:00]>
EVENT_ALM_BS_REPORT_N ---1019
BID EID STATE PARA1 PARA2 PARA3 PARA4 PARA5 RESV TIME
4 R_LOF end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:45
4 R_LOF start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:46
4 R_LOS end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:47
4 R_LOS start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:48
4 R_LOF end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:48
4 R_LOS end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:50
#9-1019:szhw [1019-Ilam ][][2012-10-23 06:32:50+00:00]>
EVENT_ALM_BS_REPORT_N ---1019
BID EID STATE PARA1 PARA2 PARA3 PARA4 PARA5 RESV TIME
4 R_LOF start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:50
4 R_LOS start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:51
4 R_LOS end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:52
4 R_LOS start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:53
4 R_LOF end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:53
#9-1019:szhw [1019-Ilam ][][2012-10-23 06:32:54+00:00]>
EVENT_ALM_BS_REPORT_N ---1019
BID EID STATE PARA1 PARA2 PARA3 PARA4 PARA5 RESV TIME
4 R_LOS end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:55
4 R_LOF start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:55
4 R_LOS start 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:55
4 R_LOS end 0x01 0x00 0x01 0xff 0xff 0xff 2012-10-23 06:32:57
The above data shows that R_LOS and R_LOF frequently end as well as begin, alternately reporting. And because our alarms are filtered with a dithering mechanism, when such jittery alarms exist, the dithering mechanism displays them as persistent alarms, so that two alarms, R_LOS and R_LOF, are observed on the host at the same time. After loopback localization, it was found that a fiber failure caused R_LOS and R_LOF.
Root Cause
The root cause of this problem is that the circuit board has received frequent alternating R_LOS and R_LOF alarms, and the host computer displays both alarms under the alarm dithering mechanism.
Solution
Emergency recovery measure: Repair the optical fiber. Complete solution measure: Repair the optical fiber.
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Co.( www.opticaltrans.com), please retain the reproduction! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Chinese
English