18529092692

Home >> News
News
OSN3500 devices report low-order insufficient resources error
| 2025-11-21|Back

Description of the problem

OSN3500 Configuration New Low Order Service Reporting Error

failed!cmd:0x802f error:0x97e2 NSERR_CFG_NO_PATH_TO_ALLOC


Processing

1. Issue the command :cfg-get-lowxc-capacity to query the current cross-board low-order resource utilization.

#0x90258:cfg-get-lowxc-capacity:9;.

LOW-XC-CAPACITY

BID MAX-CAPACITY MAX-VC4-NUM LEFT-SRC-VC4-NUM LEFT-DST-VC4-NUM LEFT-DST-VC12-NUM LEFT-DST-VC3-NUM

9 5 32 3 0 548 3

Total records :1

Explanation of the meaning of the field:

MAX-CAPACITY: Low-order cross-capacity of the current cross-board in G. The low-order cross-capacity here is 5G.

MAX-VC4-NUM: the number of VC4s of the source and host of the current low-order chip of the cross-single board. The number of VC4s here is 32.

LEFT-SRC-VC4-NUM: The number of source VC4s remaining for the current cross-single board low-order chip. The source VC4 remaining here is 3.

LEFT-DST-VC4-NUM: The number of remaining host VC4s for the current cross-single board low price chip. Here, there are 3 remaining host VC4s.

LEFT-DST-VC12-NUM: the number of remaining host VC12s for the current cross-single low price chip. Here, there are 548 remaining host VC12s. Since the service configuration will only go from 1 to N (1 <= N <= MaxVc12Num), all commands do not need to list the number of remaining source VC12s.

LEFT-DST-VC3-NUM: the number of remaining host VC3s of the current cross-single board LVCC. Here, there are 3 remaining host VC3s. Since the service configuration will only go from 1 to N (1 <= N <= MaxVc3Num), all commands do not need to list the number of remaining source VC3s.

To configure the VC12 service, ensure that the number of remaining source VC4s and the number of remaining host VC12s are not 0. To configure the VC3 service, ensure that the number of remaining source VC4s and the number of remaining host VC3s are not 0.

2. Through the query result, you can know that the number of low-order chip out VC4 (LEFT-DST-VC4-NUM) is all occupied. If you configure another host for a low-order service that is not the same as the host (slot-optical-port-VC4) of any currently configured low-order service, an error is reported.

3. how can you verify that the remaining source VC4s are really all used? To count all the cross-services and SNCP-configured services of this network element, count how many VC4s are used by each single board and optical port, and the sum of the sums is the number of VC4s used.

4. how to verify the remaining host VC3 and the remaining host VC12 usage. you can refer to 3.


Root Cause

Insufficient low-order resources


Solutions

Optimize the service or replace the high-capacity low-order cross-capacity cross veneer.


The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in the sales of Huawei SDH optical transmission equipment, SDH transmission equipment.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板