Description of the problem
OSN3500 SNCP multi-ring tangent with upstream SNCP inversion triggers SNCP multi-level inversion. Use the meter to test this service, and the meter will reflect the inversion overrun.
Processing
None
root cause
none
Solution
The reason for the long SNCP inversion time is due to the fact that before the first SNCP inverts, it transmits alarms to the downstream SNCP, and this SNCP then inverts. The downstream SNCP will also transmit alarms to the downstream SNCP first, and then this SNCP will be inverted, and so on, and the downstream SNCPs may all be inverted. This way the service shows a period of time on the also meter side to break a good ...... , the meter inversion test will consider it as a long short, so much so that the service overruns. See the documentation for more information.
Recommendations and Summary
Configuration requirements for SNCP multi-ring tangent sites:
(1) Configure the working and protection paths of the two sets of homologous SNCP protection at the SNCP ring tangency site to be opposite.
(2) Configure the SNCP service of the two homologous SNCP services at the SNCP ring tangency point to be restored.
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Co.com (www.opticaltrans.com). reproduced and retained! Our company specializes in the sale of Huawei SDH optical transmission equipment,SDH transmission equipment.