Description of the problem

The PWE3 service is opened between the PEG8 single board of OSN7500 and the PEG8 of another OSN7500. use the meter to send the test data with packet length 600 from end A to end B. Through RMON monitoring. the RMON of the GE port of end A can see that the number of received packets (512-1023) is around 16000 packets/second; And the number of packets sent on GE port of B end corresponding to the packet length is 0.

OSN7500 version is 5.21.31.65.


Processing

1、Maybe the TUNNEL in the middle does not work;

2、The PW in the middle does not work;

3, QOS configuration or insufficient remaining bandwidth;

4, other reasons.

Root cause

Mismatch of data veneer versions at both ends


Solution

1, respectively, A and B end of the TUNNEL and PW ping test, the test is all normal, indicating that the intermediate channel is not abnormal;

2、Check the configuration of PW and TUNNEL, and the CIR of each station of this PWE3 service is configured as 100M;

3, check the B end of the PEG8 board has opened a number of services, while the A end of the PEG8 board is the first time on the business, suspect that the board is a newly inserted board, check the board version found to be 1.52, and OSN 7500 corresponding to the host version of version 5.21.31.65 version of the PEG8 board version should be 3.14;

4, the use of integrated in the U2000 in the network element software upgrade function, load the software of the single board, and supporting the table check, only the PEG8 version is low, after upgrading, the meter again send packet test, the B end of the GE port RMON look at the number of packets sent (512-1023) has also reached 16,000 packets / sec.

Recommendations and Summary

In the upgrade scenario, due to the upgrade process, open the single board version of the business will be inconsistent for a period of time, the existence of this problem may be a big risk, due to the non-complementary version of the test is not perfect enough, it is recommended that the upgrade process to consider this risk, and verification tests.

Check the version matching relationship before expanding the capacity, and include the software upgrade in the expansion to unify the version matching steps


The technical information related to this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板