Description of the problem

A customer's current network found that Metro1000 devices, when there are RLOS alarms on the line boards, do not have RSUAS performance counts when querying performance.


Process

1, according to the problem phenomenon in the laboratory into the simulation. The phenomenon is:

a. When the line veneer exists RLOS alarm after configuring the service, the RSUAS count can be counted normally.

b.When no service is configured, RSUAS counts will not be counted even if RLOS alarms exist on the line veneer.

2. Code analysis based on the above phenomenon reveals the following design in the code:

When the channel in the optical port is set to enable, the performance statistics at this time will count the following performance: high-order channel, channel adaptation (pointer performance), multiplexing segment level, regeneration segment level.

The channel is set to enable in the following cases: configuration service, or the primary channel in the case of multiplexed segment protection.

This design exists for the following box devices: Metro100, Metro500 , Metro1000, OSN500, OSN550.

For NGSDH equipment or OSN9500 equipment, it does not depend on whether or not the service is configured to decide whether or not to count the segment-level performance.


Root Cause

The product is designed so that when the channel in the optical port is set to enable, the performance statistics will count the following performances: high-order channel, channel adaptation (pointer performance), multiplexing segment level, and regeneration segment level.

Solution

If you need to count the segment-level performance, you can configure the service.

Recommendations and Summary

None


The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain the reproduction! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix Metro1000_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix Metro1000_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板