Description of the problem
Broadcasting and other customer groups often use PL3 single boards to carry 45M unidirectional broadcasting services from downstream to local, and in the case of large-scale use of unidirectional broadcasting services, the PL3 single boards in the whole network will have "T3 line-side coding violation error code seconds(S)" "T3 line-side coding violation serious error code seconds(S)" abnormal performance events. )" abnormal performance events;
The performance events are displayed on the network management as follows:
Monitoring object Performance event Monitoring period Start time Performance value
405-AA-15-N2PL3-1 (under provincial station 1)-PPI:1 T3 line side coding violation statistics 15 minutes 2012-03-27 11:15:00 7247097
405-AA-15-N2PL3-2(under provincial station 2)-PPI:1 T3 line side code violation stats 15 minutes 2012-03-27 11:15:00 7246705
405-AA-15-N2PL3-3(under station X)-PPI:1 T3 line side coding violation count 15 minutes 2012-03-27 11:15:00 7246977
405-AA-15-N2PL3-1(under provincial station 1)-PPI:1 T3 line side coding violation BER seconds(S) 15 minutes 2012-03-27 11:15:00 111
405-AA-15-N2PL3-2(under provincial station 2)-PPI:1 T3 line side coding violation error code sec(s) 15 min 2012-03-27 11:15:00 111
405-AA-15-N2PL3-3(under X station)-PPI:1 T3 line side coding violation error code sec(s) 15 min 2012-03-27 11:15:00 111
405-AA-15-N2PL3-1(under provincial station 1)-PPI:1 T3 line side coding violation serious error code sec(s) 15 min 2012-03-27 11:15:00 111
405-AA-15-N2PL3-2(under provincial station 2)-PPI:1 T3 line side coding violation serious error code sec(s) 15 min 2012-03-27 11:15:00 111
405-AA-15-N2PL3-3(under X station)-PPI:1 T3 line side coding violation serious error seconds(S) 15 minutes
Alarm message
P-LOS alarms are reported on the ports of PL3 boards that have "T3 line-side coding violation severe error code seconds(S)".
Processing
Unidirectional broadcasting service generates this abnormal performance event and P-LOS alarm, which is a normal phenomenon, and the corresponding P-LOS alarm can be blocked.
Root Cause
The PL3 single board carries one-way broadcasting service down to the local area, and no service signal is input to the single board receiving channel, which will report the P-LOS alarm accordingly, and the performance event of "T3 line-side coding violation BER second" is the feedback of the performance event of the P-LOS alarm. Therefore, the reason for this performance event and the P-LOS alarm is that the PL3 port is accessing a unidirectional downlink broadcast service, and there is no service signal input to the receiving channel;
Solution
One-way broadcast service generates this abnormal performance event and P-LOS alarm, which is a normal phenomenon, and the corresponding P-LOS alarm can be blocked.
Suggestion and Summary
The one-way broadcast service from PL3 bearer to local will generate P-LOS alarm and "T3 line side coding violation error seconds", which are normal phenomena, and the service will not be affected.
The technical information and SDH equipment troubleshooting procedures in this chapter are provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Huawei SDH Optical Transmission Equipment, SDH Transmission Equipment Sales


Chinese
English