Description of the problem
On a certain day, the customer feedbacks that when adding an SLO1 single board by pre-configuring OSN3500 on U2000 network management, it is prompted that the single board does not support dynamic ports when adding ports, with the error code: 1090593570, as shown in the figure:
prescription
After querying the network management from T2000V2R2 new OSN dynamic port management function, OSN1500/2500/3500/7500 devices 5.*.13.10 later version to support dynamic ports, so if you want to add dynamic ports need to change the preconfigured version of the network element is greater than 5.*.13.10, and check the network management of preconfigured OSN 3500 versions The default version is 5.21.12.10, which is too low. After modification, it can be configured normally.
The technical information related to this chapter and the troubleshooting process of SDH equipment is provided by Shenzhen Optical Transmission Network Technology Co.(www.opticaltrans.com), please retain! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales