Description of the problem
OSN3500 device N5EFS0 newly opens Ethernet service, and finds that it cannot bind the time slot, and the management network element network management corresponds to T2000V200R006C03.
Process
1、Verify the problematic boards in slots 3 and 4, physically N5EFS0, logically configured as N4EFS0, without service, and at the same time, slot 5 EFT8, with service and normal, also found that there are remaining resources, but can not be bound, the management of the network element network management corresponds to T2000V200R006C03
2, try to pre-add N4EFS0 in slot 14, you can bind VC12, indicating that the business board can not bind the time slot is an isolated phenomenon, the network element function should be normal!
3、Replace slot 3 and 4 to slot 14 and 15, EFS0 can bind the time slot, the problem is solved.
4, but in the process of processing again found a new problem: the configuration of SDH services, can not select the time slot, verify that the business is normal.
5, verify the host 18.50P01, single board version and host matching
6、Backup network element database, upload, start and stop the network management process can not be solved.
7, due to the lack of command-line tools, can not carry out command-line business configuration verification
8、Considering that the SDH business configuration has been handled before, and the SDH cross-page display type is abnormal, and restart the client to solve the situation, try to restart the client, and sure enough, the problem is solved.
Solution
Restart the client to solve the problem.
Suggestions and Summary
Client-side problems can lead to abnormal webmaster displays.
The related technical information and SDH equipment troubleshooting procedures in this chapter are provided by Shenzhen Optical Transmission Network Technology Co., Ltd (www.opticaltrans.com), please retain! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales


Chinese
English