OSN3500 Device B1 BER Calculation Formula
| 2025-11-21|Back

Description of the problem

Bit Error Rate Calculation Formula


Solution

BER calculation formula:

B1 BER = number of B1 BER blocks / (N x 270 columns x 9 rows x 8bit x 1 second x 8000 frames/second)

Note: N is the N in STM-N

B2 BER = number of B2 BER blocks/{[(261 columns × 9 rows) + (9 columns × 5 rows)] × 8bit × 1 second × 8000 frames/second)}

B3 BER = number of B3 BER blocks / (261 columns × 9 rows × 8 bit × 1 second × 8000 frames / second)


The related technical information in this chapter and the troubleshooting process of SDH equipment are provided by Shenzhen Optical Transmission Network Technology Co., Ltd (www.opticaltrans.com), please retain the reprint! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales