The OSN2500 SSQ2SAP veneer board is available in two functional versions, Q1 and Q2. The main difference between the two versions is the different indicators on the panel. the Q1SAP veneer board has been discontinued. The single board is the system auxiliary interface board, which is applied in the OptiX OSN system to provide various management interfaces and auxiliary interfaces. The single board provides various management interfaces and debugging interfaces, etc. for the system, and provides centralized backup of +3.3V power supply and other functions for each single board of the subrack. The single board consists of overhead processing module, system communication module and power monitoring module. The single board has jumpers that can be used to set the input voltage used by the equipment and to test the official telephone. The single board can be inserted in slot 14 of the subrack. failure of the SAP single board causes the PIU single board to falsely report the POWER_ABNORMAL alarm, which can be eliminated by replacing the SAP single board.
OptiX OSN 2500
Failure Category
- POWER_ABNORMAL
Phenomenon Description
The power input unit of OSN 2500 uses 1+1 backup, and the backup 23-PIU board reports POWER_ABNORMAL alarm.
Cause Analysis
The OSN 2500 monitors two independent input power supplies from the subrack through the SAP veneer. The device supports -48V/-60V voltage input, and the input voltage is set through the J9 and J10 jumpers on the SAP single board:
- Unplugged jumper cap: the device uses an input voltage of -60V, and the power supply voltage is between -48V and -72V.
- Insert the jumper cap: the system uses a power supply with an input voltage of -48V and a power supply voltage between -38.4V and -57.6V.
When the input voltage is out of the above range, the PIU veneer will report the POWER_ABNORMAL alarm. If the SAP veneer fails, it may also cause this alarm to be reported.
Procedure
- Test the input voltage of OSN 2500 at the site and it shows normal.
- Reset the SAP board, the alarm does not go away, suspect SAP hardware failure.
- Replace the SAP single board and the alarm disappears, proving that the SAP single board is faulty.


Chinese
English





