OSN3500 network element business processing board reports BD_STATUS and COMMUN_FAIL
| 2025-11-21|Back

OSN3500 SSN1AUX single board is the system auxiliary interface board, applied in the OptiX OSN system to provide various management interfaces and auxiliary interfaces.The SSN1AUX board provides various management interfaces and auxiliary interfaces for the system, and provides centralized backup of +3.3V power supply for each board in the sub-frame, and other functions and features. There is a jumper switch J9 at the bottom right of the board, which is used to set the subrack as the main subrack or expansion subrack.The veneer can be plugged into the slot 37 of the subrack. there is a LAN Switch communication module on the veneer, and the communication between the veneers is realized through the AUX veneer. When most of the veneers have communication failure alarms, the AUX veneer failure should be considered first.

OptiX OSN 1500

OptiX OSN 1500

Failure Category

  • COMMUN_FAIL
  • BD_STATUS

Phenomenon Description

The OSN 1500 is configured with dual-crossover/master control boards Q2CXL16, N1SLQ1, N1SLQ4, interface boards D12B, PD1, power supply board PIU, and communication processor board AUX, and all single boards except D12B and Q2CXL16 report BD_STATUS and COMMUN_FAIL alarms.

Cause Analysis

Analyzing the alarm parameters collected from each board, 0x03 indicates that the Ethernet communication between boards is faulty, and it can be determined that the COMMUN_FAIL alarms of each board are caused by the Ethernet port. the AUX board also reports BD_STATUS alarms, while the crossover/master board does not report any alarms. Therefore, it is determined that the AUX single board has a communication failure with each line board.

The Ethernet communication of the AUX single board is divided into two VLANs based on the ports, one for the master single board and one for other single boards. When the AUX veneer has a communication port failure with the veneer that is not the main control, there is a phenomenon that all line veneers report COMMUN_FAIL and BD_STATUS alarms, while the main control veneer does not report this alarm. Therefore, it is concluded that the port on which the AUX veneer communicates with other veneers has failed.

Operation Procedure

  1. After replacing the AUX single board, the alarms of each single board disappear and the fault is eliminated.
The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com). Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to telephone consultation!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板