OSN3500 line board misconnections cause SDH equipment to report APS_INDI alarms
| 2025-11-21|Back

When OSN3500 browses alarms in the network management, select the alarm, and the related parameters of the alarm will be displayed in the "Alarm Details". The format of alarm parameters is "Alarm Parameters (hexadecimal): Parameter 1 Parameter 2...Parameter n". Refer to the following table for the meaning of each parameter.This alarm means that a fiber break has occurred. This alarm means that an event such as fiber break or terminal node failure has occurred, triggering a multiplexing segment inversion. After this alarm is generated, for two-fiber ring multiplexing segments and linear multiplexing segments, if another fiber break or other failure occurs, it will cause service interruption. The service is interrupted during the protection inversion period (≤50ms). The service is resumed after the normal completion of the reversal. The alarm is reported abnormally due to the line connection error when the SDH network is looped. Therefore, special attention should be paid to the connection between network elements when the equipment is networked.

OptiX OSN 3500

OptiX OSN 3500

OptiX OSN 3500 II

Fault category

  • Protection reversal fault
  • Pointer Adjustment
  • APS_INDI

Phenomenon Description

An SDH network is a 4 x VC-4 MSP ring as shown in Figure 1.

Figure 1 SDH network connection diagram

Site 1 is the center site, and other site services converge at Site 1. The clock source at site 1 is an external clock, and the other sites track the westbound line clock. Site 2 and site 3 between the fiber break, but the service is not interrupted. At the same time, site 1, 3, 4, 5, 6 have pointer adjustment performance, site 1, 3, 5, 6 are reported APS_INDI alarm, site 4 has no alarm.

Cause Analysis

Under normal circumstances, if sites 2 and 3 have intermittent fiber, sites 3, 4, 5, and 6 report APS_INDI alarms. Site 4 does not report a PS alarm, and the service is normal, which indicates that the westbound circuit board at site 4 can receive normal service from site 1. Therefore, the fiber connection at site 4 may be incorrect. That is, the westbound line at site 4 is connected to the westbound line at site 5, and the eastbound line at site 4 is connected to the eastbound line at site 3.

Procedure

  1. Check the fiber optic connection at site 4 and find that the connection is incorrect. After the correct connection, site 4 reports the APS_INDI alarm.

Reference Information

None.



The technical information in this chapter and the related SDH equipment troubleshooting process are provided by Shenzhen Optical Transmission Network Technology Co.(www.opticaltrans.com), please retain the reprint. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales Huawei OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Huawei OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板