OSN3500 motherboard failure causes SSN4GSCC to report HARD BAD
| 2025-11-21|Back

The OSN3500 motherboard failure caused the main control board to operate abnormally and continuously report HARD_BAD alarms, and the failure was ruled out by replacing the subrack.

OptiX OSN 3500

OptiX OSN 3500

Failure Category

HARD_BAD

Phenomenon Description

The main control board has been reporting HARD_BAD alarm for a long time.

Cause analysis

Analyzing the HARD_BAD alarm parameter, when parameter 5 is 0x04, it shows that the Ethernet communication port between the single boards has failed. From this, analyze the following three possible causes:

  1. The main control board is faulty.
  2. Auxiliary interface board failure.
  3. Motherboard failure.

Operation Procedure

  1. Pull out the backup master board and keep only the master board, the HARD_BAD alarm does not disappear. Then locate the failure of the main master board, the auxiliary interface board, or one of slot 17.
  2. If the HARD_BAD alarm still does not disappear after replacing the master control board in slot 17, the possibility of a faulty master control board is ruled out.
  3. Insert the main control board into slot 18 of the backup main control board and the backup main control board into slot 17 of the main control board. After switching the slots, slot 17 still reports the HARD_BAD alarm. Then locate one of the failures of the standby master board, the auxiliary interface board, or slot 17.
  4. After switching slots, the backup master board is in slot 17. If the HARD_BAD alarm still does not go away after replacing the backup master board in slot 17, rule out the possibility that the backup master board has failed.
  5. After replacing the auxiliary interface board, the HARD_BAD alarm still does not disappear, so the possibility of auxiliary interface board failure is ruled out, and the fault is localized in slot 17.
  6. Observe that the motherboard is not inverted, then exclude the possibility of motherboard failure caused by motherboard inverted pin.
  7. Replace the subrack and the HARD_BAD alarm disappears.

Reference information

None.


The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板