OSN3500 When the input optical power of the box fiber amplifier 62COA is higher than the locked output optical power value. optical power amplification is not achieved and instead attenuates by 2 dBm. you are able to troubleshoot the problem by controlling the power input at the upstream site.
OptiX OSN 3500
OptiX OSN 3500
Failure Category
OUT_PWR_ABN
Phenomenon Description
- When the input signal optical power of the Box Fiber Amplifier 62COA is between -43dBm and -20dBm, but higher than the locked output optical power value, the output optical power attenuates by 2dBm, and the 62COA fails to work normally.
- The device reports the OUT_PWR_ABN alarm.
Cause Analysis
The default locked output optical power of the Box Fiber Amplifier 62COA is -26dBm, and when the optical power of the input signal of the 62COA is higher than -26dBm, the 62COA fails to work normally.
Operation steps
- Add an optical power attenuator at the upstream signal transmitting site, and it is recommended that the optical power value input to the 62COA is between -39dBm and -26dBm.
Refer to the message
The "Locked Output Optical Power" is only available for the 62COA Box Fiber Amplifier.
The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!