The temperature of the Huawei OSN3500 crossover unit is too high, and the temperature alarm is reported for a long time, which leads to the PQ1 veneer abnormality and the reporting of the LPBBE performance event, and it is necessary to ensure that the temperature of the equipment's operating environment is in the normal range in routine maintenance.

OptiX Products

OptiX OSN 3500

OptiX OSN 3500 II

Fault Class

  • Error Code
  • TEMP_OVER

Phenomenon Description

As shown in Figure 1, site 1 is a gateway network element, and there are only aggregation services between other sites and site 1. The clock source of site 1 is an external clock source, and the other sites track the westbound line clock source. An anomaly occurs in the service between site 1 and site 6, and the PQ1 boards at both sites report LPBBE and LPES performance events, and there are also error codes on the channel that generates the performance events. Also, historical alarms show that site 6 has reported TEMP_OVER alarms over time.

Figure 1 Topology of the transport network

Cause Analysis

Site 1 and 6 reported performance events, the problem may occur on site 1, 5 and 6, which can be localized by loopback operation. Site 6 has reported a temperature alarm, which may be a high ambient temperature, resulting in a failure of the PQ1 or EXCSA veneer.

Procedure

  1. Loop back internally to the SL16 veneer at site 5, and the performance event on site 1 disappears. Once the inner loopback is removed, the performance events reappear again. This indicates that the problem should be on site 5 or 6.
  2. Outer loopback to SL16 veneer at site 6, the performance event on site 1 disappears. Once the outer loopback is released, the performance events reappear again. This indicates that the problem should be at site 6.
  3. After replacing the PQ1 and SL16 boards at site 6 with spare boards, the performance events still exist.
  4. It is certain that the crossover unit has failed. After replacing the EXCSA board, the performance event disappeared. Due to the failure of the air conditioner at site 6, the space in the server room is small and the ambient temperature is too high, resulting in damage to the crossover unit.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板