OSN1800V TNF5SL64D is a 2-channel STM-64 optical interface board. It is used in OptiX OSN series devices to realize the reception and transmission of 2-channel STM-64 optical signals.SL64D optical interface board belongs to TDM single board. The SL64D is a TDM board, which is used to complete the photoelectric conversion of STM-64 signals, extract and insert overhead bytes, and report alarms generated on the line.The SL64D board consists of a photoelectric conversion module, an overhead processing unit, a logic control unit, and a clock unit.The SL64D board needs to occupy one slot. Support CWDM color optical interface, CWDM optical interface supports 70km transmission distance. Supports DWDM color optical interface, DWDM optical interface supports 40km and 80km transmission distance.STM-64 optical interface supports 10km and 40km single-fiber bi-directional pluggable optical module. Supports 2-way SDH line clock. The laser safety level label indicates that the laser safety level of the optical interface is CLASS 1, which indicates that the maximum output optical power of the single-board optical interface is less than 10 dBm (10 mW).

TNF5SL64DFunctions and Features

Functions and Features

Description of the TNF5SL64D

Basic Functions

Receive and transmit 2-channel STM-64 optical signals.

Optical interface specifications

  • Provides I-64.1, S-64.2b and P1L1-2D2 standard optical interfaces, of which the characteristics of I-64.1 and S-64.2b optical interfaces are in accordance with ITU-T G.691 recommendations, and the characteristics of P1L1-2D2 optical interfaces are in accordance with ITU-T G.959 recommendations.
  • Support CWDM color optical interface, CWDM optical interface supports 70km transmission distance.
  • Support DWDM color optical interface, DWDM optical interface supports 40km and 80km transmission distance.

Optical module specifications

  • Support optical module information detection and query.
  • STM-64 optical interface supports 10km and 40km single-fiber bi-directional pluggable optical modules.
  • XFP pluggable optical module supports hot-swapping.
  • It supports laser on and off setting and laser auto shutdown function.

DCN

Supports out-of-band DCN.

Service Processing

  • Supports VC-12/VC-3/VC-4 services and VC-4-4c/VC-4-16c/VC-4-64c cascade services.

Overhead processing

  • Handling of segment overhead for STM-64 signals.
  • Provides D1-D3 and official byte channels.
  • Supports setting and querying of J0/J1/C2 bytes.

Pointer Handling

AU pointer processing.

Alarm and Performance

Provides rich alarms and performance events for easy device management and maintenance.

Protection Mode

  • Support two-fiber bidirectional multiplexing segment ring protection.
  • Supports linear multiplexing segment protection.
  • Support SNCP protection.
  • Supports SNCTP protection when used with TNZ5UXCMS/TNZ5XCS master control.

Over Temperature Protection

When the working temperature of the single board is too high, exceeding the temperature threshold, and has affected the business, the single board will automatically reset the key chip to avoid single board damage.

Line Clock Source

Support 2-channel SDH line clock.

Maintenance features

  • Supports inner loopback and outer loopback at the optical port level.
  • Supports inner loopback and outer loopback for VC-4 channels for quick fault localization.
  • Supports BER overrun/degradation threshold setting.
  • Supports soft reset and hard reset, soft reset does not affect service.
  • Supports query function of single board manufacturing information.
  • Support the online loading function of FPGA.
  • Support hot-plugging of single board.
  • Provide laser auto shutdown function. (Compliant with ITU-T G.664 standard)

SDH ASON

Supported when used with TNZ5UXCMS/TNZ5XCS master control.

2M ASON↵

Supported when used with TNZ5UXCMS/TNZ5XCS master.

TNF5SL64D single board can be inserted in Slot 1 to Slot 14 of 1800V chassis, the single board needs to occupy one slot.

TNF5SL64D SDH Optical Interface Parameter Description

Fields

Value field

Description

Port

-

Displays the corresponding SDH interface.

Optical Port Name

-

Displays or sets the optical port name.

Laser Switch

On, Off

Default: on

Displays or sets the interface laser switch status.

Only the SDH optical interface board supports this parameter. Normally, the setting is "On".

Optical (Electrical) Interface Loopback

No Loopback, Inner Loopback, Outer Loopback

Default: No loopback

Displays or sets the loopback status of the SDH interface.

  • "No loopback" means cancel or do not perform loopback operation.
  • "Inner loopback" means loopback the SDH signal sent to the opposite end.
  • "External loopback" means loopback of the received SDH signal.

This function is generally used for fault localization of each SDH interface. "Optical (electrical) port loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution.

In general, the setting is "No Loopback".

VC4 Channel

Example: NE(9-1001)-1-SL64D-1(SDH-1)-VC4:1

The corresponding VC4 channel is displayed.

VC4 Loopback

No loopback, inner loopback, outer loopback

Default: no loopback

Displays or sets the loopback status of the line unit's VC4 channel.

  • "No loopback" means that the loopback operation is canceled or not performed.
  • "Inner loopback" means to loopback the VC4 signal sent to the opposite end.
  • "Outer loopback" loops back the received VC4 signal.

This function is generally used for fault localization of each VC4 channel. "VC4 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution.

Under normal circumstances, the setting is "No Loopback".

VC3 Channel

Example: NE(9-1001)-1-SL64D-1(SDH-1)-VC4:1-VC3:1

The corresponding VC3 channel is displayed.

VC3 Loopback

No loopback, inner loopback, outer loopback

Default: No loopback

Displays or sets the loopback status of the VC3 channel of the line unit.

  • "No loopback" means that the loopback operation is canceled or not performed.
  • "Inner loopback" means to loopback the VC3 signal sent to the opposite end.
  • "Outer loopback" loops back the received VC3 signal.

This function is generally used for fault localization of each VC3 channel. "VC3 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution.

Under normal circumstances, the setting is "No Loopback".

VC12 Channel

Example: NE(9-1001)-1-SL64D-1(SDH-1)-VC4:1-VC12:1

Displays the corresponding VC12 channel.

VC12 Loopback

No loopback, inner loopback, outer loopback

Default: No loopback

Displays or sets the loopback status of the VC12 channels of the line unit.

  • "No loopback" means that the loopback operation is canceled or not performed.
  • "Inner loopback" means to loopback the VC12 signal sent to the opposite end.
  • "External loopback" loops back the received VC12 signal.

This function is generally used to locate faults on each VC12 channel. "VC12 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution.

Under normal circumstances, the setting is "No Loopback".

Table 2 Description of laser auto-shutdown parameters

Fields

Value field

Description

Optical interface

Example: NE(9-1001)-1-SL64D-1(SDH-1)

Displays the corresponding optical interface.

Auto shutdown

Prohibit, Allow

Default: Prohibit

Displays or sets the "Auto Off" status of the laser.

Laser auto shutdown is a function to shut down the laser automatically when the optical interface does not carry service, fiber failure, or loss of received optical signal.

When "Allow" is set, "On Time (ms)","Off Time (ms)" and"Long On Test Time (ms)" can be set. ".

On time (ms)

Example: 2000

Displays or sets the time to test whether the fiber is normal if the laser is turned on automatically after it is turned off.

Off time (ms)

Example: 60000

Displays or sets the time for the laser to turn off automatically (this parameter can be set only when the laser auto off function is enabled).

Long open test time (ms)

Example: 90000

Display or set the time to test whether the fiber is normal or not after turning off the laser, if the laser is turned on manually.


The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.


Sell OSN1800V TNF5SL64D_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
OSN1800V TNF5SL64D_Troubleshooting_Installation_Tuning_Technical Specification_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板