Supply Huawei OSN3500 SSN2EFT8 Ethernet Transmission Processing Board
| 2025-11-21|Back

Huawei OSN3500 SSN2EFT8 works with ETF8 to realize 16-channel Ethernet electrical signal access. With EFF8 to realize 8-channel Ethernet optical signal and 8-channel Ethernet telecommunication signal access.N1EFT8: Supports 1518Byte~1535Byte message length setting, ports 1~4, 9~12 support Jumbo frames not larger than 6144Byte, ports 5~8, 13~16 support Jumbo frames not larger than 9600Byte.N2EFT8 : Supports 1518Byte to 9600Byte message length settings, and supports Jumbo frames no larger than 9600Byte.

Huawei OSN3500 SSN2EFT8 Technical Specifications

The EFT8 single-board metrics include Ethernet performance metrics, mechanical metrics, and power consumption.

Interface Metrics

The electrical interface metrics of the EFT8 single board are shown in Table 1.

Table 1 Interface Metrics
Type Description
FE electrical interface FE electrical interface (RJ-45/EoS)

Huawei OSN3500 SSN2EFT8 Ethernet Performance Specification

Description:

The following is an example of the N1 version to test the EFT8 single-board throughput, overload packet loss rate, delay, and back-to-back metrics.

The test environment for the EFT8 single-board throughput, overload packet loss rate, and delay metrics is shown in Figure 1.

Figure 1 Test environment for throughput, overload packet loss rate and delay metrics

The test environment of EFT8 single-board back-to-back metrics is shown in Figure 2.

Figure 2 Test environment for back-to-back metrics

Table 2, Table 3, Table 4 and Table 5 list the throughput, overload packet loss rate, delay and back-to-back metrics of EFT8 single board, respectively.

Description:
  • The test environment configuration and networking are different, and the VC services bound to the VCG side are different, resulting in different metrics values, which are based on the actual environment test values.
  • The following metrics are configured for EPL services with 63 VC-12 test values bound to the FE port.
  • The data network performance analyzer uses SmartBits. The following test values are the test results of SmartApplication software in SmartBits instrument.
  • The test results depend on the SmartApplication settings, and the measurement results in the table are the values displayed by the meter.
  • In the table of each index of the single board, for example: "(01,01,01)", it indicates the device number, slot number and port number of the SmartBits meter in turn. "(01,01,01) to (01,01,02)" and "(01,01,02) to (01,01,01)" represent the forward test value and reverse test value. Please refer to "SmartApplications Help" for the detailed description of each setting parameter.

Table 2 lists the EFT8 single-board throughput metrics. The data in the table is collected in SmartApplication with the following settings:

  • It needs to be tested under the condition of configuring point-to-point pass-through service without enabling flow control.
  • The allowable packet loss rate for the test is set to 0% and the resolution is set to 0.1%.
  • The test time is set to 60 seconds.
Table 2 EFT8 Single Board Throughput Metrics
Frame Size (byte) Passed Rate (%) (01,01,01) to (01,01,02) (pks/sec) (01,01,02) to (01,01,01) (pks/sec) Total (pks/sec)
64 100.00 148810 148810 297620
128 100.00 84459 84459 168918
256 100.00 45290 45290 90580
512 100.00 23496 23496 46992
1024 100.00 11973 11973 23946
1280 100.00 9615 9615 19230
1518 100.00 8127 8127 16254

Table 3 lists the EFT8 single board overload packet loss rate metrics. The data in the table is collected in SmartApplication with the following settings:

  • Point-to-point pass-through service needs to be configured and tested without enabling flow control.
  • The test traffic starts at throughput and increments to 100% traffic in 10% steps.
  • The test time is set to 60 seconds.
Table 3 EFT8 Single Board Overload Packet Loss Rate Metrics
Frame Size (byte) Rate Tested (%) (01,01,01) to (01,01,02) (%) (01,01,02) to (01,01,01) (%) Average (%)
64 100.00 0.000 0.000 0.000
128 100.00 0.000 0.000 0.000
256 100.00 0.000 0.000 0.000
512 100.00 0.000 0.000 0.000
1024 100.00 0.000 0.000 0.000
1280 100.00 0.000 0.000 0.000
1518 100.00 0.000 0.000 0.000

Table 4 lists the EFT8 single board latency metrics. The data in the table is collected in SmartApplication with the following settings:

  • Point-to-point pass-through service needs to be configured and tested without enabling flow control.
  • The test time is set to 60 seconds.
  • There are two types of delay: Cut Through and Store Forward, Cut Through calculates the difference between the time when the first bit of the sent frame reaches the output port of the DUT and the time when the first bit of the sent frame reaches the input port of the DUT, Store Forward calculates the difference between the time when the first bit of the sent frame reaches the output port of the DUT and the time when the last bit of the sent frame reaches the output port of the DUT. Store Forward calculates the difference between the time when the first bit of the sent frame reaches the output port of the DUT and the time when the last bit of the sent frame reaches the input port of the DUT. In the table, the index CT is the test value under Cut Through, and S&F is the test value under Store Forward.
Table 4 EFT8 Single Board Delay Metrics
Frame Size (byte) Rate Tested (%) (01,01,01) to (01,01,02) (us)-CT (us) Average (CT) (us) (01,01,01) to (01,01,02) (us)-S&F (us) Average (S&F) (us)
64 100.00 506.4 506.4 501.2 501.2
128 100.00 518.8 518.8 508.5 508.5
256 100.00 536.2 536.2 515.8 515.8
512 100.00 578.9 578.9 538.0 538.0
1024 100.00 653.4 653.4 571.4 571.4
1280 100.00 688.1 688.1 585.6 585.6
1518 100.00 720.6 720.6 599.1 599.1

Table 5 lists the EFT8 veneer back-to-back metrics. The data in the table is collected in SmartApplication with the following settings:

  • It needs to be tested under the condition of configuring point-to-point pass-through service without enabling flow control.
  • Set SmartApplication software parameters: frame length from 64 bytes to 1518 bytes, packet rate is 100%, test time is 2s, and the number of repetitions is more than 50.
  • The test traffic is set to line speed.
  • The test time is set to 10 seconds.
Table 5 EFT8 Single Board Back-to-Back Metrics
Frame Size (byte) Rate Tested (%) (01,01,01) to (01,01,02) Burst Size (frames) (01,01,02) to (01,01,01) (frames) Total (frames)
64 100.00 297620 297620 595240
128 100.00 168918 168918 337836
256 100.00 90580 90580 181160
512 100.00 46992 46992 93984
1024 100.00 23946 23946 47892
1280 100.00 19230 19230 38460
1518 100.00 16254 16254 32508

Huawei OSN3500 SSN2EFT8 mechanical indicators

The mechanical indicators of the EFT8 board are as follows:

  • Veneer size: 25.4mm (W) x 235.2mm (D) x 261.4mm (H)
  • Weight: 1.0kg

Power consumption

The maximum power consumption of the EFT8 veneer at room temperature (25°C) is 26W.



This chapter of technical information and related SDH equipment troubleshooting process is provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), reproduced with permission. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to telephone consultation!


Sales OSN3500 SSN2EFT8_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500 SSN2EFT8_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板