Introduction to the Metro1000 device POWER_FAIL alarm parameter
Alarm information
None
Processing
A:
I. Alarm parameters distinguish between 43SCB and 46SCB:
1. On SS43SCB, the meaning of alarm parameters is as follows:
0x01: +5V
0x02: -5V
0x03: +12V
0x04: -12V
0x05: Dead Battery Alarm
0x07: Second +5 power supply failure
2、On SS46SCB, the meaning of alarm parameters is as follows:
0x01: +12V
0x02: -12V
0x03: +5V
0x04: -5V
0x3b: Second +5 power supply failure
Second, POWER_FAIL alarm is not monitored on the device by default, the command to open alarm monitoring in 43SCB/46SCB is as follows:
:alm-set-monevent:17,0,0,true;//43SCB
:alm-set-monevent:11,POWERFAIL,0,0,0,enable;//46SCB