Problem Description

Q:

Introduction to the Metro1000 device POWER_FAIL alarm parameter

Alarm information

None

Processing

A:

I. Alarm parameters distinguish between 43SCB and 46SCB:

1. On SS43SCB, the meaning of alarm parameters is as follows:

0x01: +5V

0x02: -5V

0x03: +12V

0x04: -12V

0x05: Dead Battery Alarm

0x07: Second +5 power supply failure

2、On SS46SCB, the meaning of alarm parameters is as follows:

0x01: +12V

0x02: -12V

0x03: +5V

0x04: -5V

0x3b: Second +5 power supply failure

Second, POWER_FAIL alarm is not monitored on the device by default, the command to open alarm monitoring in 43SCB/46SCB is as follows:

:alm-set-monevent:17,0,0,true;//43SCB

:alm-set-monevent:11,POWERFAIL,0,0,0,enable;//46SCB

Root Cause

None

Recommendations and Conclusions

None

END


This chapter of technical information and related SDH equipment troubleshooting process provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales Optix Metro1000_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply Optix Metro1000_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板