POWER_ABNORMAL reported on Optix OSN1500 PIU veneer boards
| 2025-11-21|Back

Problem Description
OSN1500 equipment 2 PIU single board reported POWER_ABNORMAL alarm, alarm parameters are: 0X01 00 01 00 FF; 0X11 00 01 00 FF
Equipment power supply situation: power supply module (can detect the voltage, load) - column header cabinet --OSN1500 device
Main control board version: 5.21.18.50P01

Alarm messages
POWER_ABNORMAL
Alarm parameters are: 0X01 00 01 00 FF; 0X11 00 01 00 FF

Processing
1, test the external voltage, including power supply module, column header cabinet, the PIU single board power cord unplugged, and then test the voltage, normal for -53V;
2, replace the two PIU single board, the fault remains;
3, due to the AUX single board monitoring sub-frame two independent -48V power supply, and over-voltage (-72V) and under-voltage (-38.4V) detection and analysis. Suspected AUX inaccurate detection of the two -48V voltage, detection of power module failure. Therefore, replace the AUX single board observation, the alarm disappeared, the problem is solved. Please see attached: AUX single board function block diagram.

Root cause
1, for PIU single board, parameter 1 has the following meanings: 0x01 means -48V A-channel (default for low-slot PIU single board) voltage, 0x11 means -48V B-channel (default for high-slot PIU single board) voltage; Parameter 2 is fixed at 0x00, and Parameter 3 is fixed at 0x01, which has no significance; Parameter 4 indicates the working status of the power supply: 0x00 means under-voltage, 0x01 means over-voltage; Parameter 5 is reserved for use. overvoltage; parameter 5 is reserved for use. According to the alarms and parameters, the two -48V voltage is too low, leading to the following possible causes:
2, external voltage input is too low
3, power cable problems
4, PIU single board failure
5, AUX single board failure

Recommendations and summary
OSN1500 equipment two-way -48V voltage detection point in the AUX single board, OSN2500 equipment two-way -48V voltage detection point in the SAP single board, OSN3500/7500 equipment two-way -48V voltage detection point in the GSCC single board, the OSN9500 devices have two -48V voltage detection points on the EMPU single board.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN1500 optical transmission equipment_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply OSN1500 optical transmission equipment_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板