18529092692

Home >> News
News
OptiX OSN3500 Setting the MAC Loopback Status of an Ethernet Port
| 2025-11-21|Back

OptiX OSN3500 MAC loopback (Ethernet interface)

Parameter Meaning

Sets the MAC loopback status of the Ethernet port. Setting the port loopback is used only for fault localization.

Impact on the system

The MAC loopback setting is a troubleshooting function that affects the services configured on the port. Setting the loopback status to "Inner Loopback" or "Outer Loopback" will interrupt the services on the port.

Parameter Value

Value range

Default value

No loopback, inner loopback, outer loopback

No loopback

The meaning of each parameter is as follows.

Parameter Options

Description

No loopback

Refers to the normal state. The device does not need to set loopback for normal operation.

Internal loopback

Refers to looping services from the cross side back to the cross side within the equipment at this end.

External loopback

Refers to the looping back of incoming traffic to an Ethernet port from the MAC layer of that port to the output within the local device.

Value Principle

When setting up a loopback, the direction of the loopback needs to be determined based on the direction of the service flow at the time of fault localization.

Correlation with other parameters

None

References

Loopback point Explanation Legend
MAC loopback

Ethernet services are looped back at the MAC layer of the Ethernet interface.


The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sell OptiX OSN3500 Optical Transmission Equipment_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply OptiX OSN3500 optical transmission equipment_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板