Optix OSN8800 TN54TSC 100Gbit/s Tributary Service Processing Board
  • The Optix OSN8800 TN54TSC single board belongs to the tributary class of single boards, realizing the interconversion between one 100GE/OTU4 service optical signal and one ODU4 electrical signal.The TSC single board consists of the customer-side optical module, the signal processing module, the control and communication module, and the power supply module.


Consultation hotline:
18529092692
Product Introduction

Products

OSN8800 TN54TSC Tributary Board Applications

TSC single board belongs to the tributary type single board, realizing the mutual conversion between one way 100GE/OTU4 service optical signal and one way ODU4 electrical signal.

The application of TSC single board in WDM system is shown in Figure 1.

Figure 1 Application of TSC single board in WDM system

OSN8800 TN54TSC (100 Gbit/s Tributary Service Processing Board) Functions and Features The TSC single board supports functions and features such as electrical layer crossing. The TSC single board functions and features are shown in Table 1. < Table 1 Functions and features of the TSC single board

Functions and featuresDescription
Basic functions

Realize the following signal interconversion:

1 x 100GE/OTU41 x ODU4

Customer-side service type

100GE: Ethernet service at a rate of 103.125 Gbit/s

OTU4: OTN service at a rate of 111.81 Gbit/s

Cross-over capability

Supports one ODU4 signal to realize cross-scheduling of services with the cross board through the backplane bus.

OTN Functions
  • Mapping processing meets ITU-T G.709 recommendations, adopting ITU-T G.709 recommended frame format and overhead processing.

  • OTU4 layer: supports SM overhead processing.

  • ODU4 layer:

    • Customer side access to 100GE, supports PM function.

    • Customer-side access to OTU4, support for PM and TCM functions, and uninvolved monitoring functions at the PM and TCM layers.

ESC function

Supported when accessing OTU4.

PRBS test function

The PRBS test function is supported on the client side only when the client side is accessing OTU4.

LPT FunctionNot supported
Error Correction Coding

FEC coding is supported on the client side only when accessing OTU4 services, in accordance with ITU-T G.709 recommendations.

Alarm and Performance Monitoring
  • Supports OTN's BIP8 byte monitoring (burst mode) to locate line faults.

  • Supports OTN performance monitoring and alarm monitoring functions.

  • Provides the following monitoring functions: laser bias current monitoring, laser operating temperature monitoring, optical power monitoring, etc.

  • Provides Ethernet RMON monitoring function.

ALS Function

Supported on the client side when accessing non-OTN services.

Test frame functionSupported only when 100GE services are accessed on the customer side.
Delay MeasurementNot supported
Physical Layer ClockSupported when 100GE/OTU4 is accessed on the customer side for synchronous Ethernet passthrough, not for synchronous Ethernet processing.
IEEE 1588v2Not supported
Electrical Layer ASONSupport
Protection Mode
  • Supports client-side 1+1 protection.

  • Supports ODUk SNCP protection.

  • Supports branch SNCP protection.

Description:

Branch SNCP protection is supported only when OTU4 is accessed on the client side.

LoopbackCustomer sideInternal loopbackSupport
External LoopbackSupported
Channel LoopbackNot Supported

Supported Protocols or Standards

Protocol or standard for pass-through (no performance monitoring)

IEEE 802.3ba

Protocol or standard for processing (with performance monitoring)

ITU-T G.805

ITU-T G.806

ITU-T G.709

ITU-T G.872

ITU-T G.7710

ITU-T G.798

ITU-T G.874

ITU-T M.3100

ITU-T G.874.1

ITU-T G.875

ITU-T G.808.1

ITU-T G.8201

ITU-T G.873.1

ITU-T G.694.1

ITU-T G.8261

ITU-T G.8262

Optix OSN8800 TN54TSC view and faceplate

The single-board panel has single-board indicators and interfaces.

Panel Diagram

The TSC single-board panel view is shown in Figure 1.

Figure 1 TSC Single Board Panel Appearance Diagram

Description:

If the device uses Huawei's cabinet, in order to avoid the cabinet door compressing the optical fiber, the single panel uses G.657A2 optical fiber; if you do not install the cabinet door or use a third-party cabinet when there is no cabinet door compressing the optical fiber, there is no restriction on the type of optical fiber.

Indicator Lights

There are 4 indicator lights on the panel of the single board:

  • Single-board hardware status light (STAT)-red, green, and yellow indicator lights

  • Service Activation Status Light (ACT)-green colored indicator light

  • Single-board software status light (PROG)-red and green indicators

  • Service warning light (SRV)-red, green, and yellow indicators

Please refer to Single Board Indicators for a detailed description of the indicators.

Interfaces

The type and purpose of each interface on the TSC single board panel is shown in Table 1.

Table 1 TSC Single Board Interface Descriptions

Interface silkscreenInterface TypePurpose
RXRX LC

Receives the service optical signal output from the customer-side equipment.

TXTX LC

Sends the service optical signal to the customer-side device.

Laser Safety Level

The laser safety level of the single board is HAZARD LEVEL 1, which represents that the maximum output optical power of the single board's optical port is less than 10dBm (10mW).

OSN8800 TN54TSC (100 Gbit/s Tributary Service Processing Board) Specifications

The single-board specifications include optical interface specifications, single-board size, weight and power consumption.

Board NameCustomer-side Fixed Optical ModuleCustomer Side Pluggable Optical Module
TN54TSCN/A

100GBASE-LR4-10 km-CFP

100GBASE-10×10G-10 km-CFP

(100GBASE-4×25G)/(OTU4-4×28G)-10 km-CFP

Description:

For warning considerations, the threshold defaults for the input optical power too low and input optical power too high alarms of the network management leave a certain margin on the basis of the sensitivity and overload point of the single board.

Customer-side pluggable optical module

Table 1 Customer-side-Pluggable-100GE Optical Module Metrics (100G BASE LR4)

Item

UnitIndicator value
Optical module type100GBASE-LR4-10km-CFP
Optical line code type-NRZNRZ
Optical Source Type-SLMSLM
Transmission Target Distancekilometers10

Transmitter characteristics at point S

Signal rate per channelGbit/s25.78125
Rate accuracyppm-100 to 100
Center wavelength per channel (Min)nm1294.53
1299.02
1303.54
1308.09
Center wavelength per channel (Max)nm1296.59
1301.09
1305.63
1310.19

Total Average Transmitted Optical Power (Min)

dBm

1.7

Total Average Transmitted Optical Power (Max)

dBm

10.5

Transmit OMA per channel (Min)

dBm

-1.3

Transmit OMA value per channel (Max)

dBm

4.5

Transmit average optical power per channel (Min)

dBm

-4.3

Transmit average optical power per channel (Max)

dBm

4.5

Minimum extinction ratio

dB

4
Minimum Side Mode Rejection Ratio

dB

30

Receiver Characteristics at R

Receiver Type

-PINPIN
Signal rate per channelGbit/s25.78125
Rate accuracyppm-100 to 100
Center wavelength per channel (Min)nm1294.53
1299.02
1303.54
1308.09
Center wavelength per channel (Max)nm1296.59
1301.09
1305.63
1310.19
Received average optical power per channel (Min)dBm-10.6
Received average optical power per channel (Max)dBm4.5
Minimum overload point OMA per channeldBm4.5
Receive sensitivity OMA per channeldBm-8.6
Maximum Reflection Coefficient

dB

-26

Description:

OMA value is the standard definition of the optical power operating range (including sensitivity and overload point), which is not convenient for engineering testing. For actual engineering tuning, just follow the values of "average optical power per channel" and total average optical power, and we recommend you to test only the total average transmit optical power. For details, please refer to "Tuning", "Tuning the branch board optical power".

Table 2 Customer-side-Pluggable-100GE Optical Module Specifications (100G BASE 10x10G)

Item

UnitIndicator Value
Optical Module Type100GBASE-10x10G-10km-CFP
Optical line code type-NRZNRZ
Optical Source Type-SLMSLM
Transmission Target Distancekilometers10

Transmitter characteristics at point S

Signal rate per channelGbit/s10.3125
Rate accuracyppm-100 to 100
Center wavelength per channel (Min)nm1521
1521 1529
1537
1537
1545 1553
1561
1569
1577
1585
1593
Center wavelength per channel (Max)nm1525
1533
1533 1541
1541
1549 1557
1565
1573
1581
1589
1597
Total Transmit Average Optical Power (Min)

dBm

4.2
Total Transmit Average Optical Power (Max)

dBm

13.5

Transmit average optical power per channel (Min)

dBm

-5.8

Average optical power sent per channel (Max)

dBm

3.5

Transmit OMA per channel (Min)

dBm

-2.8
Transmit OMA per channel (Typ)

dBm

-0.8
Transmit OMA per channel (Max)

dBm

3.5
Minimum extinction ratio

dB

2.5
Minimum Side Mode Rejection Ratio

dB

30

Receiver Characteristics at R

Receiver Type

-PINPIN
Signal rate per channelGbit/s10.3125
Rate accuracyppm-100 to 100
Center wavelength per channel (Min)nm1521
1521 1529
1537
1537
1545 1553
1561
1569
1577
1585
1593
Center wavelength per channel (Max)nm1525
1533
1533 1541
1541
1549 1557
1565
1573
1581
1589
1597
Received average optical power per channel (Min)dBm-10.8
Received Average Optical Power per Channel (Max)dBm3.5
Minimum overload point OMA per channeldBm3.5
Receiving sensitivity OMA per channeldBm-8.8
Maximum Reflection Coefficient

dB

-26

Description:

OMA value is the standard definition of the optical power operating range (including sensitivity and overload point), which is not convenient for engineering testing. For actual engineering tuning, just follow the values of "average optical power per channel" and total average optical power, and it is recommended to test only the total average transmission optical power. For details, please refer to "Tuning", "Tuning the branch board optical power".

Table 3 Customer-side-Pluggable-100GE/OTU4 Optical Module Specifications

Item

UnitIndicator Value
Optical Module Type(100GBASE-4×25G)/(OTU4-4×28G)-10km-CFP
Optical line code type-NRZNRZ
Optical Source Type-SLMSLM
Transmission Target Distancekilometers10

Transmitter characteristics at point S

Signal rate per channelGbit/s

100GE: 25.78125

OTU4: 27.952493

Rate accuracyppm

100GE: -100 to 100

OTU4: -20 to 20

Center wavelength per channel (Min)nm1294.53
1299.02
1303.54
1308.09
Center wavelength per channel (Max)nm1296.59
1301.09
1305.63
1310.19
Total transmitted average optical power (Min)

dBm

100GE: 1.7

OTU4: 3.5

Total Transmit Average Optical Power (Max)

dBm

100GE: 10.5

OTU4: 8.9

Transmit average optical power per channel (Min)

dBm

100GE: -4.3

OTU4: -2.5

Average optical power sent per channel (Max)

dBm

100GE: 4.5

OTU4: 2.9

Transmit OMA per channel (Min)

dBm

-1.3 (100GE only)
Transmit OMA per channel (Max)

dBm

4.5 (100GE only)
Eye diagram mode frame-100GE: Conforms to IEEE 802.3b.

100GE: Conforms to IEEE 802.3ba Recommended Template

OTU4: Conforms to ITU-T G.959 Recommended Template

Minimum extinction ratio

dB

100GE: 4

OTU4: 7

Minimum Side Mode Rejection Ratio

dB

30

Receiver Characteristics at R

Receiver Type

-PINPIN
Signal rate per channelGbit/s

100GE: 25.78125

OTU4: 27.952493

Rate accuracyppm

100GE: -100 to 100

OTU4: -20 to 20

Center wavelength per channel (Min)nm1294.53
1299.02
1303.54
1308.09
Center wavelength per channel (Max)nm1296.59
1301.09
1305.63
1310.19
Received average optical power per channel (Min)dBm

100GE: -10.6

OTU4: -8.8

Received Average Optical Power per Channel (Max)dBm

100GE: 4.5

OTU4: 2.9

Minimum overload point OMA per channeldBm4.5 (100GE only)
Receive sensitivity OMA per channeldBm-8.6 (100GE only)
Receive equivalent sensitivity per channeldBm-10.3 (OTU4 involved only)
Minimum overload point value per channeldBm2.9 (OTU4 only)
Maximum reflection coefficient

dB

-26

Description:

OMA value is the standard definition of the optical power operating range (including sensitivity and overload point), which is not convenient for engineering testing. For actual engineering tuning, just follow the values of "average optical power per channel" and total average optical power, and it is recommended to test only the total average transmission optical power. For details, please refer to "Tuning", "Tuning the branch board optical power".

Mechanical Parameters

  • Panel size: 25.4 mm (W) x 220 mm (D) x 264.6 mm (H)

  • Weight: 1.5 kg

Power consumption

Panel NameTypical Single Board Power Consumption (W)Maximum power consumption of single boarda (W)
TSC65.080.0
a: Maximum power consumption refers to the value measured at the maximum ambient temperature during normal operation of the device.




Huawei TN54TSC Purchase Price_Product Description_Hardware Description_Technical Parameters_Product Features-Huawei SDH Transmission Equipment Sales

Supply Optix OSN8800 TN54TSC Quotation_Agent Price_Sales Manufacturer_Product Supplier-Huawei SDH Transmission Equipment Sales

Online Ordering
Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML