Protection requirements

I. Panel
OptiX 155/622H Metro1000 SS42PT3T E3/T3 interface board panel diagram
Figure 1 Panel diagram of PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single board
| Functions and features | Metro1000 SS42PE3S | Metro1000 SS42PE3D | Metro1000 SS42PE3T | Metro1000 SS42PT3S | Metro1000 SS42PT3D | PT3T |
|---|---|---|---|---|---|---|
| Basic Functions |
|
|||||
| Mapping Processing | Maps E3 or T3 signals into the VC-4 by asynchronous mapping and multiplexing. | |||||
| Overhead Processing | Channel overhead processing at VC-3 level. Supports setting and querying of overhead bytes such as J1 and C2. | |||||
| Alarm and Performance | Provides rich alarms and performance events for easy device management and maintenance. Supports the alarm reversal function. | |||||
| Clock Source | PE3S/PT3S provides 1 channel reference clock source. PE3D/PT3D/PE3T/PT3T provides 2 channel reference clock source. | |||||
| Protection Mode | Supports SNCP protection with inversion time less than 50ms. | |||||
| Maintenance Characteristics |
|
|||||
| Parameter | Description |
|---|---|
| Interface rate | 34368kbit/s, 44736kbit/s |
| Interface Impedance | 75Ω |
| Line Code Type |
T3: B8ZS E3: HDB3 |
| Connector | SMB coaxial connector |
| Output port signal bit rate | G.703 compliant |
| Allowable Frequency Bias at Input | |
| Input Attenuation | |
| Input jitter tolerance |
T3: G.824 compliant E3: G.823 compliant |
The PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single boards have single board indicators, interfaces, and barcodes on the faceplate.
The panel of the PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single board is shown in Figure 1.
The E3/T3 electrical interface of the PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single board is on the panel and is an SMB type coaxial connector, the number on the connector indicates the serial number of the interface, Tx indicates the transmitter side and Rx indicates the receiver side.
The PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single board realizes the receiving and transmitting of the E3/T3 electrical signals, and completes the processing of the overhead of the VC-3 channel as well as the generating of the respective alarm signals on the branch.
The functions and characteristics of the PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single board are shown in Table 1.
III. OptiX 155/622H Metro1000 SS42PT3T E3/T3 Interface Board Specifications
PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single-board technical specifications include electrical interface specifications, single-board dimensions, single-board weight, and so on.
The technical specifications of PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single boards are shown in Table 1.
The mechanical specifications of PE3S/PE3D/PE3T/PT3S/PT3D/PT3T single boards are as follows:
The maximum power consumption of the PE3S/PE3D/PE3T/PT3S/PT3D/PT3T veneer at room temperature (25°C) is 7.0W.