Figure 1 Configuration task flow for EPLAN services

Table 1 Description of configuration task flow for Metro1000 EPLAN services
The EPLAN service can provide users with Layer 2 switching-based LAN services with multipoint connectivity.
Configuration of EPLAN services requires the use of an Ethernet switching veneer. See Table 1 for Ethernet single-board switching veneer support for EPLAN services.
| Procedure | Operation | Remarks |
|---|---|---|
| 1 |
Configure the external port of the Ethernet single board |
Required When a network element accesses Ethernet services through the external port of the Ethernet single board, it is necessary to configure various attributes of the external port in order to cooperate with the data communication equipment on the customer side to realize normal access to Ethernet services. |
| 2 |
Configuring the internal ports of the Ethernet single board |
Required When a network element transmits Ethernet services to the SDH side through the internal port (i.e., VCTRUNK) of the Ethernet board, various attributes of the VCTRUNK port need to be configured in order to cooperate with the Ethernet single board on the opposite side of the network element to realize the transmission of Ethernet services in the SDH network. |
| 3 |
Creating Ethernet LAN Services |
Required When using an Ethernet switchboard to carry LAN services, you need to create a bridge and set various attributes of the bridge and the ports to which the bridge is connected. |
| 4 |
Modify the Hub/Spoke attributes of the port on which the bridge is connected. |
Optional In the Ethernet LAN service, if you do not want multiple access nodes other than the aggregation node to communicate with each other, you can modify the Hub/Spoke attribute between the access nodes from the default Hub to Spoke. |
| 5 |
Create SDH Service |
Required. In order for Ethernet services to be transmitted through the specified time slots on the transmission line, a cross-connection between the VCTRUNK-bound channel and the corresponding time slot on the line board needs to be created. |
| 6 |
Configure Layer 2 switching characteristics.
|
Optional
|
| 7 |
Testing the Ethernet service channel |
Required. After completing the Ethernet service creation, you need to verify the connectivity of the Ethernet service. |
| 8 |
Set the performance monitoring parameters of the network element |
Required Start the performance monitoring of the specified network element to obtain the detailed performance record of the network element during operation, which is convenient for the maintenance personnel to monitor and analyze the operation status of the network element. |
| 9 | Backup network element database to the main control board |
Required Ensure that the main control board of the network element can automatically resume operation after losing data or powering down the device by backing up the network element database operation. |


Chinese