18529092692

Home >> News
News
Metro1000 EPLAN Service Configuration Any Steps
| 2025-11-21|Back

Figure 1 Configuration task flow for EPLAN services

Table 1 Description of configuration task flow for Metro1000 EPLAN services

The EPLAN service can provide users with Layer 2 switching-based LAN services with multipoint connectivity.

Configuration of EPLAN services requires the use of an Ethernet switching veneer. See Table 1 for Ethernet single-board switching veneer support for EPLAN services.

Procedure Operation Remarks
1

Configure the external port of the Ethernet single board

Required

When a network element accesses Ethernet services through the external port of the Ethernet single board, it is necessary to configure various attributes of the external port in order to cooperate with the data communication equipment on the customer side to realize normal access to Ethernet services.

2

Configuring the internal ports of the Ethernet single board

Required

When a network element transmits Ethernet services to the SDH side through the internal port (i.e., VCTRUNK) of the Ethernet board, various attributes of the VCTRUNK port need to be configured in order to cooperate with the Ethernet single board on the opposite side of the network element to realize the transmission of Ethernet services in the SDH network.

3

Creating Ethernet LAN Services

Required

When using an Ethernet switchboard to carry LAN services, you need to create a bridge and set various attributes of the bridge and the ports to which the bridge is connected.

4

Modify the Hub/Spoke attributes of the port on which the bridge is connected.

Optional

In the Ethernet LAN service, if you do not want multiple access nodes other than the aggregation node to communicate with each other, you can modify the Hub/Spoke attribute between the access nodes from the default Hub to Spoke.
5

Create SDH Service

Required.

In order for Ethernet services to be transmitted through the specified time slots on the transmission line, a cross-connection between the VCTRUNK-bound channel and the corresponding time slot on the line board needs to be created.

6

Configure Layer 2 switching characteristics.

  • Create MAC address table entries
  • Modify the MAC address aging time
  • Configure the STP/RSTP protocol

Optional

  • Create VLAN unicast table entries to manually specify the forwarding ports for MAC frames; create disabled table entries to block the forwarding of certain MAC frames. None of these manually created MAC table entries are affected by the aging time.
  • The default aging time for dynamic MAC address table entries on Ethernet switching boards is 5 minutes, and the aging time can be modified according to actual needs.
  • To prevent possible loops in the network topology of Ethernet services, STP or RTSP protocols need to be enabled, thus avoiding the proliferation and infinite loops of messages in the looped network.
7

Testing the Ethernet service channel

Required.

After completing the Ethernet service creation, you need to verify the connectivity of the Ethernet service.

8

Set the performance monitoring parameters of the network element

Required

Start the performance monitoring of the specified network element to obtain the detailed performance record of the network element during operation, which is convenient for the maintenance personnel to monitor and analyze the operation status of the network element.

9 Backup network element database to the main control board

Required

Ensure that the main control board of the network element can automatically resume operation after losing data or powering down the device by backing up the network element database operation.


Sell Huawei Metro1000_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply Huawei Metro1000_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板