Metro1000 is the more commonly used Metro series products in small and medium-sized substations, also known as OptiX155/622H.
Metro1000 can be installed in 19-inch cabinets, in 19-inch development racks, in ETSI 300-deep cabinets, in access network cabinets and wall-mounted in eight installation methods.
Its dimensions are 436mm (L) x 293mm (W) x 86mm (H) and it meets the certification of the international IEC297 for 19-inch 2U standard plug-in box design specification.
Metro1000 weighs less than 10kg and consumes less than 100W.
Metro1000 can be connected to 220V AC power supply board (90-300), -48V DC power supply board (-36~-72V) and 24V power supply (18V~36V). And different power supply boards correspond to different hardware devices, except for 220V AC, the rest of them adopt two ways of main and backup.
Users in the substation, communication equipment metro1000 commonly configured as follows:
1) The main equipment includes SS4B1CASE total assembly chassis (-48V); SS49SCBG System Control Board
SS42OI2-D(S-1.1 SC) 2xSTM-1 Optical Interface Board (S-1.1,SC)
SS-OI2-S(S-1.1 SC) STM-1 Optical Interface Board (S-1.1,SC);SS42SP2(75)
16xE1 Electrical Interface Board (75ohm);SS-EFS 4-Port Fast Ethernet Electrical Interface Board with Lanswitch Function
SS-EFS 4-port Fast Ethernet Electrical Interface Board with Lanswitch Function
2) Installation materials are as follows:
Telephone business telephone; SS-OP-FC-SC-S-20 fiber optic connector
-FC/PC-SC/PC-Singlemode-20m; SS-DL-4E1-75-10 Repeater Cable
-10m-75ohm-4E1-2.2mm-(FB4x6)-(SYFVZ75-1.2/0.25x8-I);
SS-OP-ATN-SC-5 Optical Fixed Attenuator
-1310/1550±20nm-5dB.-SC/PC-40dB
Table 1 VCTRUNK Channel Binding Requirements for Ethernet Single Boards
| Single Board |
VCTRUNK Channel Binding Requirements |
|
SS42ET1D
|
- Only VC12 level channel binding is supported.
- Supports 16 VCTRUNKs.
- VCTRUNK1 through VCTRUNK16 can only bind VC4 No. 1 (VC4-1).
|
|
SS42ET1O
|
- Only VC12 level channel bindings are supported.
- Supports 16 VCTRUNKs.
- VCTRUNK1 through VCTRUNK16 can only bind VC4 No. 1 (VC4-1).
|
|
SS42ET1
|
- Only VC12 level channel bindings are supported.
- Supports 16 VCTRUNKs.
- VCTRUNK1 through VCTRUNK16 can only bind VC4 No. 1 (VC4-1).
|
|
SS42EF1
|
- Supports only VC12 level channel bindings.
- Supports 16 VCTRUNKs.
- VCTRUNK1 through VCTRUNK16 can only bind VC4 number 1 (VC4-1).
|
|
SS42EFT
|
- Supports only VC12 and VC3 level channel bindings.
- 4 VCTRUNKs are supported.
- When selecting a VC12 level of channel binding, VCTRUNK1 through VCTRUNK4 can only bind VC4 No. 2 (VC4-2).
- When VC3 level binding channels are selected, VCTRUNK1 to VCTRUNK4 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2).
|
|
ELT2
|
- Only VC12 and VC3 level channel bindings are supported.
- Supports 2 VCTRUNK.
- When selecting a VC12 level of channel binding, VCTRUNK1 and VCTRUNK2 can only bind VC4 No. 2 (VC4-2).
- When selecting a VC3 level of binding channel, VCTRUNK1 and VCTRUNK2 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2).
|
|
SS45EGT
|
- Only VC12 and VC3 level channel bindings are supported.
- 1 VCTRUNK is supported.
- When selecting a VC12 level of channel binding, VCTRUNK1 can only bind VC4 No. 2 (VC4-2).
- When selecting a VC3 level of channel binding, VCTRUNK1 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2).
|
|
SS49EFS
|
- Only VC12 and VC3 level channel bindings are supported.
- 24 VCTRUNK are supported.
- When selecting a VC12 level of channel binding, VCTRUNK1 through VCTRUNK12 can only bind VC4 number 2 (VC4-2); VCTRUNK13 through VCTRUNK24 can only bind VC4 number 4 (VC4-4).
- When selecting the binding channel of VC3 level, VCTRUNK1 to VCTRUNK12 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2); VCTRUNK13 to VCTRUNK24 can only bind VC4 No. 3 and No. 4 (VC4-3 to VC4-4).
|
|
SS42EFSC
|
- Only VC12 and VC3 level channel bindings are supported.
- 24 VCTRUNK are supported.
- When selecting a VC12 level of channel binding, VCTRUNK1 through VCTRUNK12 can only bind VC4 No. 2 (VC4-2); VCTRUNK13 through VCTRUNK24 can only bind VC4 No. 4 (VC4-4).
- When selecting the binding channel of VC3 level, VCTRUNK1 to VCTRUNK12 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2); VCTRUNK13 to VCTRUNK24 can only bind VC4 No. 3 and No. 4 (VC4-3 to VC4-4).
|
|
SS45EGS
|
- Only VC12 and VC3 level channel bindings are supported.
- 24 VCTRUNK are supported.
- When selecting a VC12 level of channel binding, VCTRUNK1 through VCTRUNK12 can only bind VC4 No. 2 (VC4-2); VCTRUNK13 through VCTRUNK24 can only bind VC4 No. 4 (VC4-4).
- When selecting the binding channel of VC3 level, VCTRUNK1 to VCTRUNK12 can only bind VC4 No. 1 and No. 2 (VC4-1 to VC4-2); VCTRUNK13 to VCTRUNK24 can only bind VC4 No. 3 and No. 4 (VC4-3 to VC4-4).
|
|
SS42EFS4
|
- Only VC12 and VC3 level channel bindings are supported.
- Supports 8 VCTRUNK.
- When selecting a VC12 level of channel binding, VCTRUNK1 through VCTRUNK8 can only bind VC4 number 4 (VC4-4).
- When VC3 level binding channel is selected, VCTRUNK1 to VCTRUNK8 can only bind VC4 No. 1 to 4 (VC4-1 to VC4-4).
|
Only one level of time slot can be bound for the same VCTRUNK of the Ethernet single board.