The OSN1500 SSQ5CXLQ41 single board has jumpers to set battery enable and ECC path selection and dip switches to set the single board operating status.
The dip switches and jumpers are for single board testing and maintenance only.
After setting the BIOS dialing code status and the single board executes the corresponding operation, before restarting the single board, you need to reset the BIOS dialing code to zero (i.e., set the binary number to 0000). Otherwise, the single board can not enter the normal operating state.
Q5CXLQ41 single board on the jumper J10, J24 and dial code SW1 position shown in Figure 1.
The description of the jumpers on the Q5CXLQ41 single board is shown in Table 1.
| Jumper | Function | Description |
|---|---|---|
| J10 | Battery enable |
|
| J24 | Maximum DCC channel selection |
|
The dialing descriptions on the OSN1500SSQ5CXLQ41 single board are shown in Table 2.
| Dial Code | Function | Description |
|---|---|---|
| SW1 | Single board operation status setting |
|
| Corresponding value | Description |
|---|---|
| 0b0000 | Running state when watchdog is turned on, default state |
| 0b0011 | Debug state when watchdog is turned off. |
| 0b0100 | Runtime state when watchdog is turned off |
| 0b1011 | Erase database |
| 0b1100 | Erase host software (including patches) |
| 0b1101 | Erase database, host software (including patches) |
| 0b1110 | Erase database, host software and NE.ini file |
| 0b1111 | Erase file system, extended BIOS and system parameter area in FLASH |