Optix OSN3500 SSN1EFS0_SSN2EFS0 and SSN4EFS0 Differences
| 2025-11-21|Back

Description of Problem

Engineer Inquiry OSN3500 Difference between SSN1EFS0, SSN2EFS0 and SSN4EFS0

Warning message

None

Processing

1. Applicable equipment

Products

OSN 7500 OSN 3500 OSN 3500T OSN 2500 OSN 2500 REG OSN 1500A OSN 1500B

n1efs0 n y y y y n n y

n2efs0 y y y y y y n n y

n4efs0 y y y y y y n n y

2. Functional Comparison

n1efs0 n2efs0 n4efs0

Substitutability No Can replace N1 version Can replace N2 and N1 versions

Maximum uplink bandwidth 622Mbit/s 1.25Gbit/s 1.25Gbit/s

Number of bindable VCTRUNKs

12 24 24

Supports soft reset No No Upgrade to R6 supports soft reset

Supported Host Versions R1 R2 Implementation (InR2 and later host versions the logic board type can be configured as SSN2EFS0, SSN1EFS0, in R1 version the logic board type can be configured as SSN1EFS0 ) R6 Implementation (InR6 and later host versions the logic board type can be configured as SSN4EFS0, SSN1EFS0, SSN2EFS0, and in pre-R6 hosts, the logical board type can be configured as SSN1EFS0, SSN2EFS0 )

Supports service types based on flow classification PORT,

PORT+VLAN ID,

PORT+VLAN PRI PORT,

PORT+VLAN ID

PORT+VLAN ID+VLAN PRI PORT,

PORT+VLAN ID

PORT+VLAN ID+VLAN PRI

LCAS version support

LCAS V1 LCAS V1 LCAS V2

Supports pure bridge functionality no no yes

Root Cause

No

Recommendations and Summary

1, SSN4EFS0 single board when N1, N2EFS0 single board use host query can not be some single board alarms, but the single board of the STAT or SRV lights will be lit to indicate that the single board exists alarms, the reason is that the N4EFS0 single board added some new alarms, but as an old single board to use, the old host did not register the new alarms, so these alarms will not be reported. These alarms are mainly: LCAS_PLCT, LCAS_TLCT, LCAS_PLCR, LCAS_TLCR, LCAS_FOPT, LCAS_FOPR, LAG_FAIL, and so on.

2、The version of SSN2EFS series veneer board that supports multi-board ID is 2.14, only this version and later versions can be used as spare parts for N1EFS veneer board

3、When making single board substitution, you need to consider whether to configure COS or not, if the configuration of COS will lead to the unavailability of COS, you need to delete the COS configuration before substitution and reconfigure COS after substitution.

4、When upgrading, if N4EFS0 is configured as N1EFS0 or N2EFS0, when loading the single-board software using the analog package, it will be loaded according to the type of single board ( N1EFS0 or N2EFS0 ) that the current single board is configured as, you need to manually remove the selection of this single board, and then use the board-level loading to upgrade the board after completing the analog package upgrade.


Supply SSN4EFS0 Ethernet board_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
SSN4EFS0 Ethernet Board_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province