Description of Problem
Engineer Inquiry OSN3500 Difference between SSN1EFS0, SSN2EFS0 and SSN4EFS0
Warning message
None
Processing
1. Applicable equipment
Products
OSN 7500 OSN 3500 OSN 3500T OSN 2500 OSN 2500 REG OSN 1500A OSN 1500B
n1efs0 n y y y y n n y
n2efs0 y y y y y y n n y
n4efs0 y y y y y y n n y
2. Functional Comparison
n1efs0 n2efs0 n4efs0
Substitutability No Can replace N1 version Can replace N2 and N1 versions
Maximum uplink bandwidth 622Mbit/s 1.25Gbit/s 1.25Gbit/s
Number of bindable VCTRUNKs
12 24 24
Supports soft reset No No Upgrade to R6 supports soft reset
Supported Host Versions R1 R2 Implementation (InR2 and later host versions the logic board type can be configured as SSN2EFS0, SSN1EFS0, in R1 version the logic board type can be configured as SSN1EFS0 ) R6 Implementation (InR6 and later host versions the logic board type can be configured as SSN4EFS0, SSN1EFS0, SSN2EFS0, and in pre-R6 hosts, the logical board type can be configured as SSN1EFS0, SSN2EFS0 )
Supports service types based on flow classification PORT,
PORT+VLAN ID,
PORT+VLAN PRI PORT,
PORT+VLAN ID
PORT+VLAN ID+VLAN PRI PORT,
PORT+VLAN ID
PORT+VLAN ID+VLAN PRI
LCAS version support
LCAS V1 LCAS V1 LCAS V2
Supports pure bridge functionality no no yes
Root Cause
No
Recommendations and Summary
1, SSN4EFS0 single board when N1, N2EFS0 single board use host query can not be some single board alarms, but the single board of the STAT or SRV lights will be lit to indicate that the single board exists alarms, the reason is that the N4EFS0 single board added some new alarms, but as an old single board to use, the old host did not register the new alarms, so these alarms will not be reported. These alarms are mainly: LCAS_PLCT, LCAS_TLCT, LCAS_PLCR, LCAS_TLCR, LCAS_FOPT, LCAS_FOPR, LAG_FAIL, and so on.
2、The version of SSN2EFS series veneer board that supports multi-board ID is 2.14, only this version and later versions can be used as spare parts for N1EFS veneer board
3、When making single board substitution, you need to consider whether to configure COS or not, if the configuration of COS will lead to the unavailability of COS, you need to delete the COS configuration before substitution and reconfigure COS after substitution.
4、When upgrading, if N4EFS0 is configured as N1EFS0 or N2EFS0, when loading the single-board software using the analog package, it will be loaded according to the type of single board ( N1EFS0 or N2EFS0 ) that the current single board is configured as, you need to manually remove the selection of this single board, and then use the board-level loading to upgrade the board after completing the analog package upgrade.


Chinese
English