The mismatch between the host version and the network management version prevents the SSN2PL3A board from being added to the network management, and the problem can be solved by upgrading the host version.
Products
OptiX OSN1500B
Fault Category
Other
Description
The PL3A board is plugged into slot 11 of OptiX OSN 1500B, but the board cannot be added through the network management. Network management version: T2000 V200R004, host version: 5.21.17.13.
Cause Analysis
Possible causes:
Host failure causes failure to add the single board.
Failure to add a single board due to a network management failure.
Procedure
Use the command line to create the PL3A veneer in slot 11 of the network element. The creation is successful, indicating that there is no problem with the host.
Query the version matching table and find that the host version and the network management version do not match.
Upgrade the network management version to T2000 V200R006, so that the host version and the network management version match, and the problem is solved.
Reference information
None.