问题描述
A ASON network reports CP_TEL_PATH_MIS (Channel Status Inconsistency at both ends of the TE link) alarms at sites B and C on a particular day, and the alarms are associated with a silver-level intelligent service layer tunnel from point A to point D with a complete path. The device version is 5.21.18.55, and the supporting intelligent version is V1R5C01B022. The networking diagram of the device is as follows: 2bb9ea754df944e1976f7c5422c1d888
告警信息
CP_TEL-PATH_MIS
B站点告警参数如下:
Path=5,Board=7,Port=1,Local path state=10,and remote path state=0;

C站点告警参数如下:
Path=5,Board=12,Port=1,Local path state=10,and remote path state=0;

Processing
According to the alarm parameters, you can get the following information:
1. Port 7-1 of site B is docked with port 11-1 of site A. The VC4:5 time slot state of port 7-1 at the local end of site B is local path state=10 (i.e., static occupancy), and the remote path state of port 11-1 at the opposite end is remote path state=0 (i.e., idle). 2. Port 12-1 of site C is in the same state as port 12-1 of site B, and the remote path state of port 12-1 of site C is remote path state=0 (i.e., idle).
2. Site C port 12-1 is docked with site D port 8-1, site C local port 12-1 VC4:5 time slot state Local path state=10 (i.e., static occupancy), and the opposite end site D port 8-1 VC4:5 time slot state is remote path state=0 (i.e., idle).

Second, through the network management again to view the service layer in the customer side of the business, found that the silver service layer tunnel without any VC12 service, consulting the customer to learn that the path of the business for the temporary scheduling business, channel use is completed above the VC12 service has been deleted.

Since the customer first establishes a silver-level service layer tunnel from A to D when establishing the VC12 service from site A to site D, and deletes all the lower-order services in the tunnel after the service scheduling is completed but does not delete the corresponding service layer tunnels, the VC4-level bidirectional crossover is automatically generated at sites B and C when establishing the service layer tunnels from site A to site D. Therefore, the customer deletes only the VC12-level services after the VC4-level crossings at sites B and C remain, which causes sites B and C to generate the CP_TEL_PATH_MIS (Channel Status Inconsistency at Both Ends of the TE Link) alarm.

After the intelligent service layer tunnels corresponding to the alarms are removed, the CP_TEL_PATH_MIS alarms at sites B and C disappear, and the problem is solved.
根因
TE链路两端通道状态不一致,可能原因如下:
1. 预留资源操作不完整,一端预留,另一端空闲;
2. 资源配置或释放操作不完全,一端为占用,另一端预留或空闲;
3. 业务转换过程不充分,一端为静态业务,另一端为智能业务;


Solution
Recommendations and Summary
When deleting tunnel services in Smart Domain, you must pay attention to the completeness of the released resources, otherwise it is very easy to generate alarms due to the inconsistency of the time slots of the TE links at both ends due to the cross-residue.



Selling OSN3500 SSN1SLQ1A_Products_Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply OSN3500 SSN1SLQ1A_Troubleshooting_Installation and Tuning Test_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板