  1. Query the COMMUN_FAIL alarm parameter through the network management or navigator command :alm-get-curdata, and confirm the specific cause of the failure according to the alarm parameter, and the meaning of each parameter is as follows:

    Parameter name

    Parameter Meaning

    Parameter 1

    Indicates the port number, fixed at 0x01.

    Parameter 2, Parameter 3

    Indicates the channel number on which the alarm is generated. Parameter 2 is fixed to 0x00, and the meaning of parameter 3 is as follows:
    • 0x01 indicates RS485 channel 1.
    • 0x02 indicates RS485 channel 2.
    • 0x03 indicates inter-board Ethernet communication.
    • 0x04 indicates inter-subrack Ethernet emergency channel.


If parameter 3 of the Optix OSN3500 COMMUN_FAIL alarm is 0x01 or 0x02, it means that channel 1 or 2 of the 485 communication of the single board is not available. If only one single board reports the alarm, it may be the fault of the single board; if more than one single board reports the alarm, it may be the fault of a single board that causes the 485 bus to fail.

Operation Steps

  1. If the alarm is reported on only one board, replace the board directly.
  2. If the alarm is reported on more than one single board, check whether the dual-crossover is configured, and the 485 communication depends on the dual-crossover board.
  3. If dual-crossover has been configured, you can collect the historical alarms, operation records, and abnormal events from the network management side, and compare and analyze the time of the first alarm with the time of the operation records and abnormal event records, and the single board that reported the alarm first or the single board that was unplugged or replaced at the earliest time of the alarm report has the greatest possibility of failure, and it is prioritized to be replaced.
  4. If the fault still exists, you can only unplug the boards one by one to investigate the faulty boards and verify whether the slots are inverted.


This chapter of related technical information and SDH equipment troubleshooting process is collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板