Description of the problem
Summary of the version status of the metro1000 device's supported Ethernet veneers, including 49EFS, 42EFT, 42ET1, 42ET1D, 42EFSC
Solution
(1) ET1V1 Single Board
42SCB is supported from 4.2.5.4 and above;
43SCB supported from 4.2.6.4 to 4.2.6.6.
46SCB supported from version R2 with guaranteed 5.37.2.22P02 support
49SCB fully supported
(2) ET1V2 single boards
43SCB from 4.2.6.10 and above all the way up to 4.2.6.50 and below only supports ET1V2 veneer, not ET1V1.
Note: From 4.02.06.50 and above, both ET1V1 and ET1V2 series of single boards can be supported.
46SCB is supported from version R2 and guaranteed to be supported by 5.37.2.22P02
49SCB is fully supported
(3) ET1D
43SCB supported from 4.2.6.20 and above
46SCB supported from version R2, guaranteed 5.37.2.22P02 support
49SCB fully supported
(4) EFT Single Board
42SCB supported from 4.2.5.6 onwards
43SCB supported from 4.2.6.40 and above
46SCB all support
49SCB fully supported
(5) EFS Single Board
43SCB supported from version 4.02.06.31 and higher
46SCB fully supported
49SCB fully supported
(6) EFSC Veneer Boards
43SCB supports EFSC veneer from 4.02.06.52 and above;
46SCB supported from version R2, guaranteed 5.37.2.22P02 support
49SCB fully supported
Recommendations and Summary
The current cases are fragmented and are summarized for easy access. In addition, regarding the R2 version of 46SCB, only the version 5.37.2.22P02 is currently available.
This chapter of related technical information and SDH equipment troubleshooting process is collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), reproduced please retain! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Chinese