Description of the problem

A customer's intelligent network needs to upgrade three silver-level services to diamond-level protection because of business needs. Two of them are upgraded successfully normally, but one of them reports an error after clicking Convert to Diamond Level Service: time slot inconsistency, upgrade failed. Error code: 40796.


Alarm Message

CP_TEL_PATH_MIS


Processing

1. The error code is an error on the device side, and it is suspected that the data on the network management side and the network element side are not synchronized, and the whole network performs the four-step method and then re-opens the operation, and the fault phenomenon remains.


2. It is impossible to specify the time slot manually during the transformation of intelligent services. According to the error message "time slot inconsistency", it is suspected that there is inconsistency in the link channel status on the path after transformation.


3. Examine the alarms on the route, and find that there is a CP_TEL_PATH_MIS alarm on one of the intermediate pass-through network elements. Confirm that one end of the alarm parameter belongs to the scenario that one end is a traditional intersection, and the other end is a free intersection. After confirming the residual crossover, delete the traditional service and then upgrade the route successfully.


4. If you think that the above troubleshooting is a waste of time, there is another method, you can display the VC4 of the corresponding single board as idle cross-corresponding board in the single board - intelligent - resource reservation is set as a reservation, and then carry out the service conversion, the equipment will not use the reserved VC4 during the conversion process, and it can be converted to a success, and then cancel the resource reservation can be.



Root Cause

The smart path conversion process is unable to manually specify a time slot, and the automatically generated path has a CP_ETL_PATH_MIS (time slot inconsistency) alarm on it as a result.



Solution

Eliminate the CP_TEL_PATH_MIS alarm or set resource reservation.


The related technical information and SDH equipment troubleshooting procedures in this chapter are provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales


Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板