18529092692

Home >> News
News
OSN3500 New Intelligent Path prompts "Network Element No Link Connected"
| 2025-11-21|Back

Problem Description

After OSN3500 has enabled the smart feature for quad synchronization, the SDH smart path management prompts "no link connection for network element" for new smart path.

Process

1. Check that the ECC communication 9-byte mode is on and normal.

2、Check the intelligent characteristic management is normal.

3. Check that the LMP protocol management status and operation status are normal.

4. Check that the OSPF protocol management status is normal.

5、Check the SDH intelligent topology management, network elements all belong to the same intelligent domain (note that if not in the same intelligent domain, you need to manually delete a smart domain and then synchronize).

6、Verify that the TE link management interface is normal and there is a TE link.

7. Verify that the upload operation must be done after opening the intelligent characteristics, otherwise some basic attributes of the intelligence are not synchronized to the network management, resulting in incomplete links in the intelligent link management of the network management, and intelligent services cannot be created.

8, on the newly opened intelligent network elements to do the upload operation, and then the four-step synchronization, the problem is solved.


Root cause

After the smart feature is turned on, you must do the upload operation, otherwise some basic attributes of the smart are not synchronized to the network management, resulting in incomplete links in the smart link management of the network management, and you cannot create smart services.


Solution

Do the upload operation for the newly opened smart network elements, and then do the four-step synchronization.


Suggestions and summaries

It is recommended to do the upload operation first, and then do the four-step synchronization for the newly opened smart network elements.

In order to ensure that the network management and equipment synchronization, end-to-end formation of business path, to facilitate routine maintenance and management, the need to use the "four-step approach", including.

1, synchronization network element cross. Network management menu for the configuration-SDH intelligent-intelligent topology management

2, synchronization TE Link, network management menu for the configuration-SDH intelligent-TE link management.

3、Synchronize Smart Path and refresh the actual route of Smart Path. The network management menu is Configuration-SDH Intelligence-Intelligent Circuit Management and Maintenance-Refresh Actual Route.

4、Path search. The network management menu is Path-SDH Path Search.


The related technical information in this chapter and the SDH equipment troubleshooting process are provided by Shenzhen Optical Transmission Network Technology Co.(www.opticaltrans.com), please retain! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales


Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板