This content introducesthe phenomenon ofpower supply failurePower_abnormalcaused by business interruption, the impact on the system, the possible causes, troubleshooting the tools needed for the failure, precautions and processing steps. Phenomenon: A large number of single boards of equipment at a site are reset at the same time, and the service is interrupted. Impact on the system: A power supply failure causes service interruption. Possible causes: Cause 1: The power consumption of the network element exceeds the threshold power consumption of the network element. Cause 2: Abnormal single-board power supply. Cause 3: Loose connector or poor contact of the power supply cable. Cause 4: External power supply interruption or abnormal power fluctuation. Cause 5: Device power board failure. Cause 6: DC power distribution box failure.
Problem Description
OSN1500 device AUX single board Power_abnormal alarm parameter details
Alarm information
POWER_ABNORMAL alarm is reported on the AUX board.
Processing
para0: fixed to 0x01;
para1: fixed at 0x00;
para2: fixed to 0x01;
para3 (converted to binary, bit 1 is valid):
bit0 // Read 1.5V voltage status abnormality of this board
bit1 // Read the 1.8V voltage status of this board abnormally.
bit2 // Abnormal reading of 3.3V from power supply module of this board
bit3 // Abnormal 3.3V status of backup power supply.
Root cause of failure
None
Recommendations and Summary
The meaning of the AUX single board Power_abnormal alarm parameter is the same in all versions of OSN1500 devices.
This chapter of related technical information and SDH equipment troubleshooting procedures provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales


Chinese
English