OSN1500 device and router 155M optical interface board interface failure
| 2025-11-21|Back

When the OptiX OSN 1500 device interfaces with the 155M optical port of the router, the 2M service reports the LP_RDI alarm, which is analyzed and found to be due to the high-order overhead of the line board being in the pass-through state, which leads to the interruption of the low-order service. Therefore, when changing from high-order service to low-order service, you need to set the overhead mode correctly.

Products involved


Huawei SDH Equipment OptiX OSN1500

Failure Category


The device fails to interface with the router service, resulting in routing failure. Business interruption, LP_RDI

Phenomenon Description


When the network is expanded and remodeled, the SLQ1 single board of the OptiX OSN 1500 equipment is directly docked with the router optical card of Company C. The network is protected by 1+1 linear multiplexing segments. The network is protected by 1+1 linear multiplexing segments, with 2M services at one end and 155M optical port services docked at the other end, in which 2M services report LP_RDI alarms.

Cause Analysis


Check the optical transmission path, time slot docking, router hardware, and SDH single board overhead mode one by one to troubleshoot the problem.

Operation Steps


After the physical connection is normal, the SLQ1 board and the optical ports of Company C receive normal optical power, and there is no optical power alarm at the receiving end, but the link status of Company C's router shows down.

Querying the alarms, it is found that there is no abnormal alarm on the SLQ1 board, but the 2M service at the other end reports the LP_RDI alarm.

Loop back internally to the docking optical port of the SLQ1 single board, and the LP_RDI alarm of the 2M service disappears, indicating that the optical transmission path is normal.

The link status of Company C's router shows up on the docking optical port of the outer loop back to SLQ1 single board, so it is suspected that the time slot is incorrectly docked.

Check the first VC-12 in VC-4 of the SLQ1 single board to see that it is also the first VC-12 in Company C. Corresponding to the 2nd VC-12 of Company C, add a 2M service on the 22nd VC-12, and the remote 2M service still reports LP_RDI alarm, suspecting that the local end fails to receive optical signals.

Reset the router, and the fault remains after reboot.

Check the SDH service configuration. The docking optical port of the SLQ1 board at this end was originally a VC-4 service, and after deleting the VC-4 service, a new VC-12 service is added, and the overhead mode should be "Termination". Query the corresponding overhead mode, and it is still "pass-through". After setting it to "Termination", the LP_RDI alarm disappears and the service is normal.

References


When configuring a low-order service, the high-order overhead of the board must be set to "Terminate", otherwise the service will be interrupted.


The technical information and SDH equipment troubleshooting procedures in this chapter are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales


Optix OSN1500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN1500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板