Large number of false codes reported on line veneer due to SSN1DCU failure
| 2025-11-21|Back

Operation Steps

  1. As the SL64 single board of station B reports the regeneration segment and multiplexing segment error code, station A receives the error code pair report from station B, which confirms that the problem is a unidirectional reception error code. Through checking the performance of network management and on-site testing, station B receives optical power of -12.7dB from station A, which is in the normal range, and excludes the reason that the received optical power is too weak.
  1. After testing the fiber connectivity, the optical fiber between station A and station B for transceiver alignment, the fault phenomenon does not shift with the fiber alignment, to rule out optical path failure.
  1. Since the configuration is a GXCSA single board, it excludes the error code caused by the matching problem with the line board.
Description:
  1. Replace the SL64 optical boards at stations A and B. The faults do not disappear, so you can rule out a single board fault.
  1. Study the network diagram, found that the distance between A and B is 100km, the rate is 10G, the configuration of the structure is "optical board + BA + PA + DCU + optical board". The BA and PA modules are examined, and no abnormality is found.
  1. Since DCU is a dispersion compensation module, it is not suitable for loopback, so DCU is removed and turned into "PA + optical board".
  1. When preparing for the loopback test, it was found that the error code changed from tens of thousands to 1 or 2. Thus, it is judged that the DCU is faulty, and the fault disappears after replacing the DCU.
Reference Information

Due to DCU failure, the equipment reported a large number of regeneration and multiplexing segment BERs, and the problem was solved after replacing the DCU.

OptiX OSN 3500

BER Problems

The SNCP ring network composed of OptiX OSN 3500 devices adopts GXCSA as cross boards and SL64 boards in the main ring, and station B receives a large number of regeneration and multiplexing segment errors reported by the SL64 board at station A. At the same time, station A receives regeneration and multiplexing segment errors reported by the SL64 board at station B. The problem is solved after replacing the DCU.

  1. There are restrictions on the use of EXCSA veneer boards. N2/T2 series boards, except T2SL64A and N2SLQ16, cannot be used with T1EXCSA veneer boards. There is no restriction on the use of GXCSA veneer boards with circuit boards.

Although the DCU single board is a piece of dispersion supplemental fiber, but there is a possibility of failure, judgment of failure should be careful, do not let any link.


Sales SSN1DCU_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply SSN1DCU_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板