OSN3500 Setting Up PDH Service Board Loopback Operation
| 2025-11-21|Back

OSN3500 Setting the PDH service board loopback operation causes service interruption. If the channel used by other services configured by the upstream network element and the channel used by this network element to report alarms are the same VC4 channel, the upstream network element cannot use the loopback method. Loopback is used for fault localization. The outer loopback can be used to test whether the interface module of the veneer and the external cable are normal, and the inner loopback can be used to test whether the cross-connection unit and the service path of the equipment are normal. This task describes how to perform a loopback operation for a PDH electrical interface board.

Prerequisites

The user has the network administrator privilege of "Network Element and Network Operator" or higher.

Impact on the System

A loopback operation reverses the downstream AIS signal. In an unprotected state, loopback may cause service interruption.

The loopback operation can only be used for fault localization, and the loopback setting for that port must be cleared after fault localization.

Tools, Instruments, and Materials

U2000

Background

The device supports PDH electrical interface board external loopback and internal loopback.

Table 1 Schematic diagram of electrical interface board loopbacks
Loopback point Explanation Legend
PDH electrical interface board outer loopback The external loopback does not change the signal structure. Inside the PDH electrical interface board, the signal from the receive port is looped back directly to the corresponding transmit port before signal processing. It can be used to determine whether the PDH interface and the fiber cable connecting to the PDH single board are normal.
Internal loopback within the PDH board The internal loopback has been signalized within the local device. Inside the PDH electrical interface board, signals from the cross-connection unit are looped back to the cross-connection unit after signal processing. It can be used to determine whether the PDH board service processing module and the cross-over board are normal.

Operation Procedure

  1. Double-click the Main Topology icon in the Workbench view to enter the Main Topology diagram.
  2. On the main topology map, select the network element that needs to be looped back. Right-click and select "Network Element Manager".
  3. Select the electrical interface board that needs to be looped back, and select "Configuration > PDH Interface" in the Function Tree.
  4. Select "By Function" and select "Branch Loopback" from the drop-down menu.
  5. Select the port to be looped back and choose "Inner Loopback" or "Outer Loopback" from the drop-down menu in the corresponding right column.
  6. Click "Apply" and the "Confirm" dialog box will pop up, click "OK". The "Prompt" dialog box pops up, click "OK".
  7. The "Result" dialog box pops up, click "Close".
  8. Optional: Undo Loopback. Set the loopback method to "No Loopback".

The technical information and SDH equipment troubleshooting procedures in this chapter are provided by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain them! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales


Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板