Parameter Meaning:Maximum Frame Length (Ethernet Port Attribute)-Sets the maximum frame length that the Ethernet port can support.
Impact on the system:When the length of user packets exceeds the set maximum frame length, the packets will be discarded or intercepted to the set frame length size. This parameter takes effect only when the message is inbound to the port, and does not affect outbound messages.
Parameter Value
|
Board Name |
Range |
Default value |
Unit |
|---|---|---|---|
|
N1EGS4, N3EGS4 |
1518~9216, step size is 2 |
1522 |
Byte |
|
N1EMS4, N4EGS4 |
1518~9216, step size is 1 |
1522 Byte |
Byte |
|
N1EFT8、N1EFT8A、R1EFT4 |
1518~1535, step size is 1 |
1522 Byte |
Byte |
|
N2EFT8, N2EFT8A, N3EAS2, N1EGSH, N1EGT2, N1EAS2, N2EMR0, N2EGR2, N4EFS0, N5EFS0, N2EFS4, N3EFS4, N2EGS2, N3EGS2, N1EFS0A, N1EMS2 |
1518 to 9600 in steps of 1 |
1522 |
Byte |
| N1EFP0 |
1518~2000 in steps of 1 |
1522 Byte |
Byte |
Principle
The maximum frame length needs to be set according to the actual situation in the application, and the default value is used if there is no special requirement from the user.
The related technical information in this chapter and the troubleshooting process of SDH equipment are provided by Shenzhen Optical Transmission Network Technology Co., Ltd (www.opticaltrans.com), please retain the reproduction! Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment Sales