OSN3500AISalarmoccursParameter Meaning "AISalarm occurs" - Sets whether or not theAISindication ofthe signal is usedas a condition for clock source reversal. Impact on the system Does not affect system operation. Parameter value Range of values Default value Yes or No. The meaning of each parameter value is as follows. Parameter Option Description Yes Use the signal'sAISindication as a sufficient condition for clock source inversion No Do not use the signal'sAISindication as any condition for clock source inversion Principle of value In practical applications, try toset the AISalarm as a condition for clock source inversion ...
Parameter meaning
"AIS alarm occurs" - sets whether the AIS indication of the signal is used as a condition for clock source inversion.
Impact on the system
Does not affect system operation.
Parameter Value
|
Value range |
Default value |
|---|---|
|
No |
The meaning of each parameter is as follows.
|
Parameter Options |
Description |
|---|---|
|
Yes |
The AIS indication of the signal is a sufficient condition for clock source inversion. |
|
No |
Do not use the AIS indication of the signal as any condition for clock source inversion. |
Principle
In practical applications, try to set the AIS alarm as a clock source inversion condition to ensure the performance of the system.
Relationship with other parameters
None
Reference Information
None
The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!